AirKing EL Serie Mode D'emploi page 3

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Screw
Figure 5
1b.
Internal Wire Compartment: If the motor is already installed in the housing, remove the
two screws holding the blower assembly in place. Lift up on the assembly and slide it
out of the tabs on the housing (Figure 6). Remove the wire compartment cover screw
and place the cover in a secure place (Figure 7).
Screws
Figure 6
NOTE: If the fan motor plug is connected to the fan housing receptacle, unplug so the blower
assembly can be completely removed.
Screw
Figure 7
Standard Models
Continuous Ventilation: For two speed fans wired for continuous ventilation, connect
2.
the White wires of the fan to the White (Neutral) wire from the power source. Connect the
ground wire from the house to the green wire from the fan housing. Connect the Black
wire of the fan to the Black wire (Hot) from the power source. Using a properly grounded
standard duplex toggle switch (such as Leviton 5224-2W, not included) connect the Black
wire from the supply to one side of the top and bottom switch. Connect the Red wire (light)
from the fan housing to the other side of the top switch and connect the Purple wire (night
light) from the fan housing to the other side of the bottom switch. Using a second properly
grounded standard duplex toggle switch, connect the Hot Yellow wire from the fan to the
input of the switch. Connect the second Yellow wire from the fan to the output side of the
switch. Closing the switch will change from normal to high speed (Figure 8).
Black
Neutral (White)
Neutral (White)
Green
Ground (Green or Bare)
Neutral (White)
Black
Figure 8
6727913 Rev. H 12-18
Wire
Compartment
Cover
Plug
Wire Compartment
Cover
NOTE: Wire compartment configuration
will be dependent on model.
Wire Compartment
Red
Black
By others
Supply from house
NOTE: The yellow wire may contain a wire crimp nut which will have to be cut off and
the wire stripped.
Motion Sensing Models
3.
For two speed fans wired for continuous ventilation, connect the White wires of the fan to
the White (Neutral) wire from the power source. Connect the ground wire from the house
to the green wire from the fan housing. Connect the Black wire of the fan to the Black
wire (Hot) from the power source. The fan will operate on low speed continuously and
boost to high speed when motion is detected. Using a properly grounded standard duplex
toggle switch (such as Leviton 5224-2W, not included) connect the black wire from the
supply to one side of the top and bottom switch. Connect the red wire (light) from the fan
housing to the other side of the top switch and connect the purple wire (night light) from
the fan housing to the other side of the bottom switch. A manual override switch (not
included) can be used to provide a manual fan Off function (Figure 9).
Black
Neutral (White)
Tabs
Neutral (White)
Black
Figure 9
Humidity Sensing Models
4.
For two speed fans wired for continuous ventilation, connect the White wires of the fan
to the White (Neutral) wire from the power source. Connect the ground wire from the
house to the Green wire from the fan housing. Connect the Black wire of the fan to the
Black wire (Hot) from the power source. The fan will operate on low speed continuously
and boost to high upon a rise in humidity. Using a properly grounded switch, connect 1
yellow wire to each side of the switch. Closing the switch will change from normal to
high speed. Using a properly grounded standard duplex toggle switch (such as Leviton
5224-2W, not included) connect the Black wire from the supply to one side of the top
and bottom switch. Connect the Red wire (light) from the fan housing to the other side
of the top switch and connect the Purple wire (night light) from the fan housing to the
other side of the bottom switch. A manual override switch (not included) can be used to
provide a manual fan Off function (Figure 10).
Black
Neutral (White)
Neutral (White)
Black
Figure 10
NOTE: The yellow wire may contain a wire crimp nut which will have to be cut off and
the wire stripped.
Humidity and Motion Sensing Models
5.
For two speed fans wired for continuous ventilation, connect the White wires of the fan to
the White (Neutral) wire from the power source. Connect the ground wire from the house
to the green wire from the fan housing. Connect the Black wire of the fan to the Black wire
(Hot) from the power source. Using a properly grounded standard duplex toggle switch
(such as Leviton 5224-2W, not included) connect the Black wire from the supply to one
Purple
side of the top and bottom switch. Connect the Red wire (light) from the fan housing to the
other side of the top switch and connect the Purple wire (night light) from the fan housing
to the other side of the bottom switch (Figure 11).
www.airkinglimited.com
Wire Compartment
Neutral (White)
Green
Ground (Green or Bare)
Black
Supply from house
Wire Compartment
Neutral (White)
Green
Ground (Green or Bare)
Black
Supply from house
Red
Purple
By others
Red
Purple
By others
3 of 16

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

El80d

Table des Matières