3.6.3 Connecting to a LAN / WAN

After installing MSView on a PC on a local network,
and with COM and power connections made, as
described in Section 2.3, 2.4, a DHCP-enabled router
will automatically assign an IP address and network
settings to the EMC-1. The Morningstar Device will also
be read for specific device information before connection
is made. After the original assignment, network settings
can be changed as desired using the LiveView Network
Web Page.
For complete connection and addressing information, see
Appendix I of the Product Connectivity Manual:
www.morningstarcorp.com/wp-content/up-
loads/2014/02/
ADVANCED TOPIC:
3.6.4 Connecting to the EMC-1 from a Remote
Location (outside of the LAN) via the
Internet / WAN
Basic Procedure:
1. Verify that the Morningstar Device is correctly
connected by accessing it via a Web browser (see
Section 3.6.2). Navigate to the Network Page.
2. In another browser window, enter the network
router default gateway IP address (probably
192.168.1.1, but see Appendix I, Section II of Product
Connectivity Manual - link below).
3. Login to the network router, and choose a static IP
address outside of the listed dynamic range.
4. Return to the LiveView Network Page window,
change the selection to, "Use Static IP Address",
enter the IP address chosen in the previous step,
15
re-enter the remaining network settings listed in the
box, including port 502, to direct incoming Internet
requests to the Morningstar Device, and port 80 to
view Morningstar Device Web pages on any Internet
connected PC, then click the "Save" button.
5. To maintain a recognizable public IP address, set
up a Dynamic DNS service, or verify your router's
Dynamic DNS capabiltiy.
The Product Connectivity Manual describes all aspects
of connectivity and programming:
www.morningstarcorp.com/wp-content/
uploads/2014/02/
See Appendix 1, Section 3 for full details.

3.7 Push-button Functions

3.7.1 Factory Reset

The EMC-1's communication settings can be restored
to the factory default conditions. The following values
will be reset:
• TCP / IP settings
• Stored non-volatile product data
To Perform a Factory Reset:
1) With the EMC-1 powered ON, press and hold the
reset button until the status (left) LED starts to flash
R-G, R-G....
2) Release the reset-button.
3) The EMC-1 will re-boot with the factory default
settings.