- Loading warm contents.
- Cold content load will delay the change to a warmer
set-point temperature.
- Warm content load will delay the change to a colder
set-point temperature.
•
Usage, (number and duration of the door openings).
•
Use of the storage compartment display lighting, (glass
door product only).
•
Installation of the appliance in direct sunlight or next to
a heat source.
Single Zone Models:
To set or check the set-point temperature (with the control
out of sleep mode), press the "-" or "+" keypads. "SET" will
be indicated on the user interface panel and the current
set-point temperature will display and flash. Subsequent
presses of the "-" or "+" keypads will adjust the
temperature colder or warmer respectively. When you have
reached your desired set-point temperature, press the
"On/Off" keypad to accept, or do nothing and the "Set"
mode will timeout in 10-seconds accepting the displayed
temperature as the new set-point.
The available set-point temperature range for your
appliance is 40°F (4.5°C) to 65°F (18.4°C). If you attempt
to adjust the temperature outside of this range you will
receive an audible notification.
Lower zone
selected
Dual Zone Models:
Temperatures can be set for each individual zone (upper
and lower) in the dual zone wine cellar. To do so you must
first select the zone you want to set the temperature for.
You do so by pressing the upper or lower button on the
display. When pressed the LED light will be illuminated for
the respective display.
To change the set temperature for a particular zone, with
the zone selected and out of sleep mode, press the "-" or
"+" keypads. "SET" will be indicated on the user interface
panel and the current set-point temperature will display and
flash. Subsequent presses of the "-" or "+" keypads will
adjust the temperature colder or warmer respectively.
USING YOUR ELECTRONIC CONTROL
When you have reached your desired set-point
temperature, press the "On/Off" keypad to accept, or do
nothing and the "Set" mode will time-out in 10-seconds
accepting the displayed temperature as the new set-point.
The available set-point temperature range for your
appliance is 45°F (7.3°C) to 55°F (12.9°C) for the lower
zone and 55°F (12.9°C) to 62°F (16.8°C) for the upper
zone. If you attempt to adjust the temperature outside of
these ranges you will receive an audible notification.
Interior display lighting (Single and Dual
Zone):
Your appliance is equipped with a dual light level display
lighting feature. With the control out of sleep mode press
the "Light" keypad once to activate the interior lighting
display feature at full illumination. A confirmation tone will
sound, and the light bulb "Icon" will illuminate. Pressing the
"Light" keypad a 2nd time will dim the lighting to 50%. A
3rd press will deactivate the display lighting feature. The
display lighting will automatically deactivate after 4-hours.
Temperature mode (Single and Dual Zone):
The temperature mode is preset from the factory in
Fahrenheit (°F) but you have the option to change it to
Upper zone
Centigrade (°C). To change the mode, press and hold the
selected
"-" keypad, while pressing the "+" keypad, then release the
"-" keypad. The temperature will now be displayed in
Centigrade (°C). Repeat the procedure to change the
temperature mode back to Fahrenheit (°F).
Control lock:
The control panel can be locked to avoid unintentional
changes. To lock the control, press and hold the "Lock"
keypad until the display reads "Loc" then immediately
release your finger from the keypad. The lock icon will flash
3-times and then continuously illuminate. When the control
panel is locked, only the Lock keypad, System Status OK
indicator , and the Alarm indicator are active. To un-lock
the control panel, repeat this instruction until the display
reads "nLc", then immediately release your finger from the
keypad.
13