Electrical Service Guide - Hobart Welding Products IronMan 250 Manuel Du Propriétaire

Table des Matières

Publicité

2-11. Positioning Jumper Links
3
1

2-12. Electrical Service Guide

Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes
Min Input Conductor Size In AWG/Kcmil
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG/Kcmil
Reference: 1999 National Electrical Code (NEC)
1 Choose a circuit breaker with time-current curves comparable to a Time Delay Fuse.
2 "Time-Delay" fuses are UL class "RK5" .
3 "Normal Operating" (general purpose – no intentional delay) fuses are UL class "K5" (up to and including 60 amp), and UL class "H" ( 65 amp and
above).
Y Caution: Failure to follow these fuse and circuit breaker recommendations could create an electric shock or fire hazard.
OM-192 440 Page 14
230 VOLTS
200 VOLTS
460 VOLTS
230 VOLTS
575 VOLTS
S-153 980
Circuit Breaker
S-144 916-A
2
1
2
, Time-Delay
Normal Operating 3
Check input voltage available at
site.
1
Jumper Links Access Door
Open door.
2
Jumper Link Label
Check label – only one is on unit.
3
Input Voltage Jumper Links
Move jumper links to match input
voltage.
Close and secure access door.
Tools Needed:
3/8 in
Ref. ST-802 285-B
200
230
460
40
35
18
50
40
20
60
50
25
8
10
14
108
94
148
(33)
(29)
(45)
10
10
14
575
14
15
20
14
232
(71)
14

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

M-25 gun

Table des Matières