Connections
The collectors are equipped with four screw connections (1 ¼" male thread) and must be connected with flat sealing to
each other or to the system connection pipes. Ensure correct placement of the flat gaskets. Length compensators must be
used as connection elements between the collectors in order to compensate the length expansion of the copper pipes dur-
ing temperature fluctuations. Attention: Check the pump design or the flow differences in the individual collectors. When
tightening the connections with the spanner, a torque of 30Nm should not be exceeded so as to prevent damage to the
manifold or absorber.
Collector inclination / general information
The collector fixing systems are designed to be assembled at 30°, 45° and 60°. The collectors are suitable for a minimum
angle of 25° and a maximum angle of 75°! The collector connections and the ventilation openings must be protected
against the penetration of water as well as against contamination through dust etc.
Guarantee
Warranty claim only in conjunction with the supplier's original frost protection and correct installation, commissioning and
maintenance. Installation by qualified personnel with strict adherence to the instructions is a prerequisite for the justifica-
tion of claims. Note: Installing solar thermal pannels (collectors) near to coastal regions or in any other corrosive envi-
ronment may result in corrusion and corrosion of the absorber. SONNENKRAFT doesn't take any responsibility or liability
for such damages if installed in such environment. If required, it is possible to contact us for a special solar panel which is
designed and suitable for such environment.