INSTRUCTION OF BRAKE FLUID
About Boiling Point
Brake Fluid Type
Dry Boiling Point
Wet Boiling Point
1. Wet boiling point is the reference temperature for changing the brake fluid.
2. Dry boiling point is the reference temperature for new brake fluid.
3. Testing accuracy of the tester: ±5%.
INSTRUCTION OF K-TYPE THERMOCOUPLE
1. Use standard K-type thermocouple
2. Measurement range: -60°C - 500°C ± (1%+3digital)
3. Measurement accuracy: -20 - 500°C ± (1%+3digital)
TESTING THE BRAKE FLUID
1. Suggest battery voltage between 12 - 13V.
2. Make sure power clips are connected tightly with correct polarity before any measurement.
3. When the device connecting with vehicle battery, the device will turn on automatically. The initial
function is A; if it is B, press and hold °C / °F switch for 3 seconds to switch back to function A
(A shall appear on LCD).
4. Both "Brake fluid cycle paths" must be immersed into the brake fluid. Make sure the brake fluid
level is higher than the "Minimal Brake Fluid Volume Position".
5. Press and hold the "Start Button" to test the brake fluid. Please keep the Brake Fluid Testing
Probe perpendicular with the brake fluid during the test.
6. lf "wait cool" appears on the LCD, please wait for the heating wire to cool down before next test.
7. User can use the "Brake fluid pipet" to draw some brake fluid into the measuring cup for testing.
CAUTION
•
After the testing, please wait at least 3 seconds for heating wire to cool down before take testing
probe out of the brake fluid.
•
Avoid the shaking and smashing of the testing probe, especially after the test.
•
If the fester doesn't use for a while, due to the residue on the sensor from last test, please test
twice to obtain a more accurate reading from second test .
•
Please shake the brake fluid before draw it for the boiling temperature test.
MEASURING WITH THERMOCOUPLE
1. Connecting the device with vehicle battery; if the function is A, press and hold °C / °F switch for 3
seconds to switch to function B, "B" shall appear on LCD.
2. Connecting the K-type thermocouple with the tester to start the measurement.
3. During function B, if K-type thermocouple is not connecting with the device or if the measured
temperature is higher than 500°C, "Hi" will appear on LCD.
4. During function B, if measured temperature is lower than -60°C, "Lo" will appear on LCD.
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
DOT 3
≥205°C
≥140°C
Tel.: 02196 720480
Fax.: 02196 7204820
mail@bgs-technic.de
DOT4
≥230°C
≥155°C
www.bgstechnic.com
© BGS technic KG, Copying and further use not allowed
DOT 5.1
≥260°C
≥180°C