release the handle, pull the lock pin ring to unlock the
handle, and turn the handle down to the storage position.
Release the ring to lock the handle in place (Fig. 8).
Transporting position
Fig. 8
Storage position
m
CAUTION!
Do not attempt to lift the unit by the handle
assembly. If it is necessary to lift the generator, always grasp
by the frame. Use proper lifting techniques to avoid back
injury.
Operation
m
DANGER!
Carbon Monoxide. Using a generator indoors
CAN KILL YOU IN MINUTES.
Generator exhaust contains high levels of carbon monoxide
(CO), a poisonous gas you cannot see or smell. If you can
smell the generator exhaust, you are breathing CO. But even if
you cannot smell the exhaust, you could be breathing CO.
• Never use a generator inside homes, garages, crawlspaces,
or other partly enclosed areas. Deadly levels of carbon
monoxide can build up in these areas. Using a fan or
opening windows and doors does NOT supply enough fresh
air.
• ONLY use a generator outdoors and far away from open
windows, doors, and vents. These openings can pull in
generator exhaust.
Even when you use a generator correctly, CO may leak into
the home. ALWAYS use a battery-powered or battery-backup
CO alarm in the home. If you start to feel sick, dizzy, or
weak after the generator has been running, move to fresh air
RIGHT AWAY. See a doctor. You could have carbon monoxide
poisoning.
m
WARNING!
This generator will be used ONLY with cord
and plug connected equipment, National Electric Code does
not require that the unit be grounded. However, other methods
of using the generator may require grounding to reduce the
risk of shock or electrocution. Consult a qualified electrician,
electrical inspector, or local agency having jurisdiction for local
codes or ordinances to find out if grounding is needed in your
situation before using the generator.
m
to make you careless. Remember that a careless fraction of a
second is sufficient to inflict serious injury.
m
not recommended by the manufacturer of this product. The
use of attachments or accessories not recommended can
result in serious personal injury.
NOTE: This product is equipped with a spark arrestor;
however, product users must comply with Federal, State,
and local fire prevention regulations. Check with appropriate
Pull the ring to
authorities. Contact Snow Joe
unlock the handle
center at 1-866-SNOWJOE (1-866-766-9563) or a qualified
service center to purchase a replacement spark arrestor.
NOTE: Before each use, inspect the entire product for
damaged, missing, or loose parts such as screws, nuts, bolts,
caps, etc. Tighten securely all fasteners and caps and do not
operate this product until all missing or damaged parts are
replaced. Please call the Snow Joe
service center at 1-866-SNOWJOE (1-866-766-9563).
This generator is designed to supply electrical power for
operating compatible electrical lighting, appliances, tools, and
motor loads.
Before Operating the Unit
NOTE: There may be General or State Occupational Safety
and Health Administration (OSHA) regulations, local codes or
ordinances that apply to the intended use of the generator.
Please consult a qualified electrician, electrical inspector, or
the local agency having jurisdiction before using the appliance.
Grounding the Generator
m
and plug-connected equipment, National Electric Code does
not require that the unit be grounded. However, other methods
of using the generator may require grounding to reduce the
risk of shock or electrocution. Consult a qualified electrician,
electrical inspector, or local agency having jurisdiction for local
codes or ordinances to find out if grounding is needed in your
situation before using the generator.
When grounding is required, the ground terminal on the frame
is used to connect the generator to a suitable ground source.
The ground path should be made with at least #12 size wire.
Loosen the ground terminal. Wind the wire on the terminal
insuring a metal to metal connection, and tighten the terminal
fully (Fig. 9). Connect the other end of the wire securely to a
suitable ground source that is in contact with the soil for a
minimum distance of 8 ft.
12
WARNING!
Do not allow familiarity with this product
WARNING!
Do not use any attachments or accessories
• Only use OUTSIDE and at least 20 feet away from windows,
doors, and vents. Your specific home and/ or wind
conditions may require additional distance.
• NEVER use inside a home or garage, EVEN IF doors and
windows are open.
• Always position the generator on a flat firm surface.
WARNING!