Ceiling Installation - Gigaset Smoke Sensor 2.0 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 48
SMOKE ALARM
INSTALLATION POSITION FOR INCLINED ROOFS
10 cm
90 cm
60 cm
10 cm
60 cm
28
Smoke Sensor 2.0
FOR INCLINED OR POINTED ROOFS
For installation to inclined or pointed ceilings, and rooms with an
inclined ceiling, smoke alarms should be installed at least 10 cm
vertically underneath the highest point, and no more than 90 cm
horizontally from the highest point.
These distances also apply when multiple alarms are installed in
one room. Install individual smoke alarms at appropriate distances
from each other.

CEILING INSTALLATION

When fitting smoke alarms to ceilings, keep a distance of at least
20 cm from walls and objects, and 60 cm from corners.
ANGLED CEILING
In rooms having a ceiling at an angle greater than 7 degrees
(corresponds to a height difference of about 50 cm over 4 m),
smoke alarms should be positioned on the ceiling in the higher
part of the room.

Publicité

Table des Matières
loading

Table des Matières