Application Examples
L1
on
A1(+) S11
S33
S34
LG5925
A2(-)
S21
N
2-channel emergency stop circuit without cross fault monitoring.
Note: Refer to "Unit programming"!
Switches in pos.:
S1 no cross fault detection
S2 manual start
Suited up to SIL3, Performance Level e, Cat. 4
L1
on
A1(+) S11
S33
S34
LG5925
A2(-)
S21
N
Activated No contact
(contact position: closed)
2-channel safety gate monitoring.
Note: Refer to "Unit programming"!
Switches in pos.:
S1 no cross fault detection
S2 manual start
Suited up to SIL3, Performance Level e, Cat. 4
E. DOLD & SÖHNE KG • D-78114 Furtwangen
e-mail: dold-relays@dold.com • internet: http://www.dold.com
E-stop
S12 S22
13
..
..
..
..
14
M6668_b
sliding guard closed
S12 S22
13
..
..
..
..
14
M6672_c
L1
on
A1(+) S11
S33
S34
LG5925
A2(-)
N
2-channel emergency stop circuit with cross fault detection
Note: Refer to "Unit programming"!
Switches in pos.:
S1 cross fault detection
S2 manual start
Suited up to SIL3, Performance Level e, Cat. 4
L1
on
A1(+) S11
S34
LG5925.54
A2(-)
N
2-channel emergency stop circuit with cross fault detection
Note: Refer to "Unit programming"!
Switches in pos.:
S2 manual start
Suited up to SIL3, Performance Level e, Cat. 4
•
PO Box 1251 • Telephone (+49) 77 23 / 654-0 • Telefax (+49) 77 23 / 654-356
20
E-stop
S12 S22
S21
13
..
..
..
..
14
M6671_b
S12 S22
S21
13
..
..
..
..
14
M10096
LG 5925 / 18.09.19 en / 152A