Circuit Diagrams; Connection Terminals; Notes; Technical Data - DOLD SAFEMASTER LG 5925 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Circuit Diagrams

A1
13
23
+
S33
S34
A1+ S11
13
23
S12
S22
K1
S33
S34
K2
A2
S21
14
24
S11
S12
S21
S22
M8573_a
A2
14
24
LG 5925.02
A1
13
23
33
+
S33
S34
43
44
A1+ S11
13
23
33
S12
S22
K1
S33
S34
K2
A2
S21
14
24
34
S11
S12
S21
S22
M8552
A2
14
24
34
LG 5925.04
A1
13
23
33
+
58
S34
41
42
41 +
A1+ S11
13 23 33
S12
K1
S22
S34
K2
A2
S21
14 24 34
42
S11
S12
S21
S22
M9721
A2
14
24
34
LG 5925.54

Connection Terminals

Terminal designation
A1+
A2
S12, S22, S33, S34
S11, S21
13, 14, 23, 24, 33, 34, 43, 44
41, 42
A1
13
23
33
+
S33
S34
41
42
A1+ S11
13
23
S12
S22
K1
S33
S34
K2
A2
S21
14
24
S11
S12
S21
S22
A2
14
24
34
LG 5925.03
A1
13
23
33
+
S33
S34
41
42
43
A1+ S11
13 23 33
S12
S22
K1
S33
S34
K2
44
A2
S21
14 24 34
S11
S12
S21
S22
A2
14
24
34
LG 5925.48
K1/K2
58
Signal description
+ / L
- / N
Inputs
Outputs
Forcibly guided NO contacts for
release circuit
Forcibly guided indicator output

Notes

Line fault detection on On-button:
The line fault detection is only active when S12 and S22 are switched
simultaneously. If The On-button is closed before S12, S22 is connected
to voltage (also when line fault across On-Button), the output contacts will
33
41
not close. A line fault across the On-button which occurred after activation
of the relay, will be detected with the next activation and the output con-
tacts will not close.
The terminal S21 permits the operation of the device in IT-systems with
34
42
insulation monitoring, serves as a reference point for testing the control
voltage and is used to connect the E-stop loop when cross fault moni-
M10536
toring is selected.
Connecting the terminal S21 to the protective ground bridges the internal
short-circuit protection of Line A2 (-). The short-circuit protection of line
A1 (+) remains active.
To alter the functions automatic start - manual start and with or without
cross fault monitoring, the switches S1 and S2 are used. These are loca-
ted behind the front cover (see unit programming).
The setting with or without cross fault monitoring on E-stop buttons is
made with S1 (not for LG 5925.54). The LG 5925.54 has always cross
41
fault monitoring.
S2 is used to change between automatic an manual restart. On automatic
start also the terminals S33 - S34 have to be linked. For connection please
42
see application examples.
M8553

Technical Data

Input circuit
Nominal Voltage U
LG 5925:
LG 5925.54:
Voltage range
AC / DC
at 10% residual ripple:
AC:
Nominal consumption at U
Min. Off-time:
Control voltage on S11 at U
Control current typ. over
S12, S22:
LG 5925:
LG 5925.54:
Min. voltage on S12, S22
when relay activated:
Short-circuit protection:
Overvoltage protection:
Output
Contacts
LG 5925.02:
LG 5925.04:
LG 5925.03 ,
LG 5925.48, LG 5925.54:
The NO contacts are safety contacts.
The NC contacts 41-42 can only be used for monitoring.
Operate delay typ. at U
Manual start:
automatic start:
Release delay typ. at U
Disconnecting the supply:
Disconnecting S12, S22:
Contact type:
Nominal output voltage:
Thermal current I
th
16
:
N
AC/DC 24 V, AC 110 ... 115 V, AC 230 V
AC/DC 24 V
0.9 ... 1.1 U
N
0.85 ... 1.1 U
N
:
DC approx. 1.5 W
N
AC approx. 3.7 VA
250 ms
: DC 22 V at AC/DC units
N
DC 24 V at AC units
30 mA at U
N
25 mA at U
N
DC 20 V at AC/DC units
DC 19 V at AC units
Internal PTC
Internal VDR
2 NO contacts
4 NO contact
3 NO, 1 NC contact
:
N
30 ms
350 ms
:
N
150 ms at AC units
50 ms at DC units
130 ms at AC units
50 ms at DC units
forcibly guided
AC 250 V
DC: see arc limit curve
:
max. 8 A per contact
see quadratic total current limit curve
LG 5925 / 18.09.19 en / 152A