Dryer Error Messages - Dexter Laundry T-30 Manuel De L'utilisateur

Masquer les pouces Voir aussi pour T-30:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

If the Overheat Sensing System has been activated, the dryer should be inspected safely and appropriately.
After inspecting the dryer, it may be returned to service by resetting the controller by pressing the RESET
button on the main control board.

13 DRYER ERROR MESSAGES

The O-Series dryer control reacts to various abnormal conditions by displaying an Error message. These
messages usually contain the "Error" text, and then a general description of the message. Below is a listing
of Error messages separated by each potential displayed message in bold face. Each is following by:
 Condition that creates the displayed message on the control
 Action that the control takes responding to the condition
 Exit is the method the user (or the control) should use to bring the machine back to normal operation.
The actual displayed message on the control may contain the general description listed below and additional
details (such as number or additional text). However, the condition, action or exit qualities of the error
message should be the same for all variations.
For non-reversing models, there is no variable frequency drive. Therefore, any of the error codes listed
below that pertain to Drive performance will not be available on those models.
OPERATION IN PROGRESS
Condition
Action
Exit
POWER LOSS
Condition
Action
Exit
BROWN OUT
Condition
Action
Exit
TEMP SENSOR SHORT
Condition
Action
Exit
8514-291-001 REV E PAGE 27
This error occurs when the user is attempting to start a machine operation
while another operation is ending.
When detected, the control does not respond to user input on the buttons.
There is no delay in the action once the criteria are met. The control will finish
the current operation while displaying "OPERATION IN PROGRESS". Once the
operation is complete, the error will no longer be displayed, and the control will
respond to user input normally.
The error will be reset automatically once the current operation is complete.
This error occurs when the Main Control Board detects a total loss of 24VAC
power.
When detected, the control turns off the motor and the heating relay. There is
no delay in the action once the criteria are met.
The machine will not start, and the Error Code will continue to be displayed
until the condition is no longer present. Once the condition is removed, the
machine still will not start, and the Error Code will continue to be displayed until
the prompt is followed to Reset the Error and return the machine to Idle Mode.
This error occurs when the Main Control Board detects less then 21VAC at the
24VAC input.
When detected, the control turns off the motor and the heating relay. There is
no delay in the action once the criteria are met.
The machine will not start, and the Error Code will continue to be displayed
until the condition is no longer present. Once the condition is removed, the
machine still will not start, and the Error Code will continue to be displayed until
the prompt is followed to Reset the Error and return the machine to Idle Mode.
This error occurs when the control detects a short circuit from the temperature
sensor.
When detected, the control turns off the motor and the heating relay. There is
no delay in the action once the criteria are met.
The machine will not start, and the Error Code will continue to be displayed
until the condition is no longer present. Once the condition is removed, the