To Fill The Gun From Bulk Container; To Fill The Gun With A Filler Pump - Lincoln Electric PowerLuber A Serie Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

To Fill The Gun from Bulk Container

1. Remove pump assembly from grease tube
assembly.
2. Pack lubricant into cavity of the pump as-
sembly.
3. Insert the open end of the grease tube
assembly into lubricant (see Fig. 3). Slowly
pull the follower handle back while pushing
the grease tube assembly deeper into the
lubricant to prevent air pockets from being
pulled into the grease tube assembly.
4. When the follower rod is fully extended,
pull it sideways to latch the rod groove
into the keyhole slot in the grease tube
assembly cap.
5. Loosely assemble the pump assembly to
the grease tube assembly. Release the fol-
lower rod from the grease tube assembly
cap and disengage the follower rod from
the follower by rotating the follower handle.
Push the follower rod into the grease tube
assembly. Slowly unscrew the grease tube
assembly from the pump assembly until
lubricant oozes from the interface. Tighten
grease tube assembly into the pump as-
sembly.
Figure 3
Form 403994
Models 1800, 1842, 1842E, 1844, 1844E
To Fill The Gun with a Filler
Pump
1. Engage the follower rod with the follower
by rotating the follower handle.
2. Insert the gun vent/bulk ill valve into the
iller pump socket (see Fig. 4).
3. Operate the iller pump to ill the container.
When the follower rod groove is exposed,
the grease tube assembly is illed. The fol-
lower rod will be extended approximately 8
inches (20 cm). Do not overill!
4. Disengage the follower rod from the
follower by rotating the follower handle.
Push the follower rod into the grease tube
assembly.
Remove Air Pocket! Air pocket at grease
inlet will prevent grease from being pumped.
Unscrew the vent/bulk ill valve two full turns to
remove small air pockets trapped in this area.
If the air pocket is substantial and no grease
lows from coupler after trigger is pulled for 15
seconds, see following steps.
To Expel Air Pockets
1.
Withdraw the follower rod from the grease tube
assembly cap and engage it with the follower by
rotating the follower handle.
2.
Unscrew the vent/bulk ill valve two turns. Exert
force on the follower handle until grease lows
through the opening in the vent/bulk ill valve.
3.
Tighten the vent/bulk ill valve.
4.
Pull the trigger in short bursts to operate gun
until trapped air is expelled. Disengage the
follower rod from the follower by rotating the
follower handle. Push the follower rod into the
grease tube assembly.
5.
If step 2 fails, unscrew the grease tube assem-
bly 1-1/2 turns from the pump assembly.
6.
Exert force on the follower handle until lubricant
oozes from the grease tube assembly and
pump assembly interface.
7.
Tighten grease tube assembly into the pump
assembly. Disengage the follower rod from the
follower by rotating the follower handle. Push
the follower rod into the grease tube assembly.
PowerLuber Grease Gun
Figure 4
Page Number - 7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

180018421842e18441844e

Table des Matières