To set this load type...
Dimming Loads
Incandescent/halogen
(tungsten)
Magnetic low-voltage
HP
loads
•
•
TM
(10 V
supply only)
GRX-ELVI loads
(Electronic low-
voltage)*
GRX-FDBI or
GRX-TVI loads
(Lutron 3-wire
fluorescent)*
Tu-Wire
compact
®
fluorescent
Neon/cold cathode
*Interface required; contact Lutron Technical Support for details .
Legend:
LED lit
LED off
R
Select this
LED display
Important Notes
*
Use for tungsten filament lamps .
NOTE: This is the factory preset load type for each
zone.
*
Use for magnetic transformer low-voltage lighting .
*
Set all zones connected to HP dimming modules
as shown—no matter what load type they are
(including non-dim or switching) . The HP can be
used to switch non-capacitive ballasts . To fine-
tune the dimming of these "HP-powered" zones,
you must adjust high and low end trim on the HPs
as described in the instructions supplied with the
unit . Do NOT use HPs with generator-supplied
line/mains voltage .
*
All electronic low-voltage (ELV) lighting used with
an electronic low-voltage interface (ELVI) must
be rated for reverse phase control/trailing edge
dimming . Refer to the documentation for your
interface .
*
Zones set for Lutron Hi-lume or Eco-10
fluorescent lighting must have GRX-FDBI or
GRX-TVI fluorescent interfaces . Contact Lutron
for more information . Refer to the documentation
for your interface .
*
Tu-Wire compact fluorescent does not require a
fluorescent dimming ballast interface (FDBI) . This
load type is not available in GRX-CE models .
*
Use for neon or cold cathode lighting .
GRAFIK Eye
3000 Series Control Unit Installer's Guide
®