  • FRANÇAIS, page 1
and night-lights that are plugged directly into an AC
receptacle to recharge.
2)Certain battery chargers for battery packs used in
hand powered tools. These chargers will have warning
labels stating that dangerous voltages are present at the
charger's battery terminals
CAUTION!
The power inverter must be absolutely connected
directly to the battery with clamps, if output 220vlt
consumption exceeds 150w, under 150w the power
inverter can be used with cigarette lighte connector.
Inverter will not work under low battery voltage, high
battery voltage will damage it.
For example:
Input for 12 VDC of inverter, links to 6VDC will not work ,
connected to the 24VDC will damage.
Input for 24 VDC of inverter, links to 12VDC will not work
, connected to the 48VDC will damage
10.

Protection function.

1)
Low voltage shutdown
Inverter set up inside Low voltage shutdown function,
when the battery voltage to reach set,inverter AC output
would automatically shut off.
For example:
Input for 12 VDC of inverter, when the battery voltage
reach 10.0 + /-0.5 V,inverter AC output would
20