Fig. 18
4. With the hose and the preferred nozzle connected, insert
the battery into the battery compartment, and press the
ON ( I ) side on the ON/OFF switch (Fig. 12). To stop the
unit, press the OFF ( O ) side of the ON/OFF switch and
remove the battery.
NOTE: During the whole blowing process, keep the air
inlet clear to maintain stable air flow.
General Operation Tips
m
WARNING!
Do not vacuum drywall dust, fireplace soot
or ash with the unit. This is very fine dust which will not be
captured by the filter and may cause damage to motor.
m
WARNING!
The foam filter must be used for wet
vacuuming, and make sure to clean the foam filter after using.
m
WARNING!
Do not use the cartridge filter and paper
dust bag for wet vacuuming. Do not use the cartridge filter for
sharp material.
• Place the equipment on a level surface that is not heat
sensitive.
• Always use the suction hose. Hold the suction hose at a
distance of approximately 0.4 in. (1 cm) above the material
to be vacuumed.
m
WARNING!
When vacuuming large quantities of liquids,
do not immerse the nozzle attachment completely in the liquid;
leave a gap at the tip of the nozzle opening to allow air inflow.
The machine is fitted with a float valve that stops the suction
action when the collection tank reaches its maximum capacity.
You will notice a decrease in motor speed. When this happens,
turn off the machine, remove the battery, and drain the liquid
into a suitable receptacle or drain.
• The air flow can be adjusted when the air regulation
Air outlet
Suction hose
• If needed, use the equipped telescopic tube to reach
• Turn off and remove the battery after vacuuming, before
• Empty the tank outside in order to avoid a mess.
• Clean or change the filters (see Maintenance section)
m
turning the power switch to the OFF position and remove the
battery.
14
handle is connected. Slide the air block as needed to
adjust the air flow (Fig. 19).
Fig. 19
Air regulation handle
further distance. Press the telescopic tube lock and
extended the tube as shown (Fig. 20).
Fig. 20
Telescopic tube
Telescopic tube
lock
cleaning and maintenance. After wet vacuuming, empty
the collection tank, clean and dry the inside and outside
before storage.
if the suction performance deteriorates. Never use the
appliance without the filter.
WARNING!
Never remove the powerhead without first
Air block