Print Settings

Keys:
,
Speed
Contrast
Key:
Transfer ribbon control
Key:
Y displacement
Key:
X displacement
Key:
Tear off

Label Layout

Keys:
,
,
Label length
Gap length
Key:
Column printing
Key:
Measure label
Key:
Label type
Key:
Material selection
Key:
Photocell
Scan position (AP)
Indication of print speed in mm/s.
Value range: 50 mm/s ... 200 mm/s (see the technical data).
Indication of value to set the print intensity when using different materials, print speeds or
printing contents.
Value range: 10% ... 200 %.
Off: The ribbon control is deselected, i.e. the printer continues without an error message.
On: The ribbon control is selected, i.e. the current print order is interrupted and an Error
Message appears at the printer display.
strong sensibility: The printer reacts immediately to the end of the transfer ribbon.
weak sensibility: The printer reacts at approx. 1/3 more slowly to the end of the transfer
ribbon.
Indication of initial point displacement in mm.
Value range: −30.0 ... +90.0.
Displacement of the complete print transverse to the paper direction.
Value range: −90.0 ... +90.0.
Indication of value to which the last label of a print order is moved forward and is moved back to
the beginning of label at a new print start.
Value range: 0 ... 50.0 mm
Standard: 12 mm.
Indication of label length in mm.
Minimum height: 5 mm (dispenser mode: 25 mm).
Indication of distance between two labels in mm.
Minimum value: 1 mm.
Indication of width of one label as well as how many labels are placed side by side.
Press key
to start measuring.
Generally adhesive labels are set. Press key
Selection of the used label and transfer ribbon material.
Selection of the used photocell.
The selection of one of the following photocell types is possible: transmission photocell normal
and inverse, reflexion photocell normal and inverse, ultrasonic photocell (option).
Entry of percental label length by that the label end is searched.