OPERATING INSTRUCTIONS
LIGHTING THE HEATER
BEFORE LIGHTING:
The supply hose that connects the LP Tank with the combustion system must have the air
purged from it and replace it with LP Gas so that the heater will light. Push the control knob
in and turn it counterclockwise to ignite. Hold it in for 3 to 4 minutes to purge the line.
For your safety, if relighting a hot heater. Always wait for at least 5 minutes.
TO LIGHT:
(A) Lift the Tank Enclosure and tilt it so it rests on the Support legs, as shown in Step 9.
(B) Make certain hose is connected to the heater intake hose and regulator is connected
to the propane tank. Check both connections to ensure they are tight and leak proof.
(C) Turn supply tank valve in a counter clockwise direction. Check for leaks by applying
soapy water to the tank and hose connections.
(D) Push and slowly turn the gas control knob to the "ignite" position (see diagram
below). Keep pushing the knob for 30 seconds until the pilot flame has warmed the
thermocouple and stays lit. Slowly release the knob and turn to desired heat level.
(E) If ignition does not occur, push and turn the knob to the "OFF" position and repeat
step #D up to 3 times.
(F) If ignition still does not occur, push and turn the knob to the "OFF" position, wait 5
minutes for the accumulated gas to dissipate, and then repeat steps D and E.
21