Conrad Renkforce 1168660 Mode D'emploi page 3

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

G Operating Instructions
Indoor Fountain Pump, 5 W
Item no. 1168660
Intended use
The pump is suitable for use e.g. in an indoor fountain, a small indoor pond or a mini
water feature.
Always observe the safety instructions and all other information included in these op-
erating instructions!
Any other use, than that described above, could lead to damage to this product and
involves a risk for short circuits, fire, electric shock, etc.
This product complies with the applicable national and European requirements. All
company names and product names are trademarks of their respective owners. All
rights reserved.
Contents
• Indoor fountain pump
• Pipe adapter for hose connection (possibly already connected to the pump outlet)
• Operating instructions
Explanation of the symbols
The lightning symbol inside a triangle is a warning to inform you of potential
risks of personal injury, such as electrical shock.
This symbol indicates specific risks associated with handling, function and
use.
The "arrow" symbol indicates special tips and operating information.
The product is designed according to Protection Class II.
Observe the operating instructions!
Safety Instructions
D amages caused by the failure to follow these operating instructions will
void the warranty/guarantee! We assume no liability for any consequential
damage!
W e assume no liability for personal injury or property damage caused by
the improper use or the failure to comply with the safety instructions! In
such cases, the warranty will be null and void.
a) General
• For reasons of safety and certification (CE) the unauthorised alteration
and/or modification of the product is not permitted.
• The product is not a toy. Devices operated using mains voltage do not
belong in the hands of children. Therefore, be especially careful when
children are around. Use the product where it is out of the reach of chil-
dren.
• The pump is designed according to Protection Class II and Protection
Type IPx8. Use only a proper power socket as source of electricity in ac-
cordance with the specifications of the public supply network.
• At commercial institutions, the accident prevention regulations of the Em-
ployer's Liability Insurance Association for Electrical Systems and Operat-
ing Facilities are to be observed!
• Do not leave packaging material lying around,carelessly; it could become
a dangerous toy for children.
• Please handle the product carefully; jolts, impacts or a fall even from a low
height can damage the product.
• If you have any questions that are not answered in these operating in-
structions, please contact our technical support centre or consult a pro-
fessional. Please consult a specialist if you have any doubts regarding the
use or safety of the product.
b) Operation
• The socket outlet to connect the pump must be easily accessible.
• The A/C power plug must not get damp or wet. Make sure, when you posi-
tion the pump, that no water runs down the power supply cord towards
the plug; the cord must form a drip loop.
Danger of electric shock!
• These pumps are not for use in swimming pools, bathtubs or showers.
• The product may be used only indoors. It is not suited for outdoor use.
• Do not pull the power plug from the mains socket by pulling on the cable.
• Make sure that the mains cable is not pinched or damaged by sharp edg-
es.
• If the pump or power cord is damaged, do not touch it; there is danger to
life from electric shock!
First, turn off the mains voltage to all poles of the mains socket to which
the pump is connected (e.g. switch off at the corresponding circuit break-
er or remove the safety fuse, then turn off at the ELCB).
Then you can remove the mains plug from the mains socket.
Do not use the pump any longer and dispose of it in an environmentally-
friendly manner. A damaged mains cable cannot be replaced!
• The pump is not suitable for dry runs; it will be destroyed after a short time
of running dry-loss of warranty. Operate the pump only when it is fully
submerged under water.
• Only clear water is permitted as the liquid to be pumped (temperature
+5 °C.....+35 °C). Never use other liquids (e.g. salt water, gasoline, heating
oil, chemicals, solvents or foodstuffs).
Connection and Getting Started
Please follow chapter "Safety Instructions".
Secure a suitable hose at the outlet connection, if necessary. Ensure that the hose is
stable and cannot work itself loose. Secure the hose, for example, with a cable tie.
Set the pump in the water, e.g. in an indoor fountain. The pump must be submerged
completely. Move the pump around somewhat so that the air in the pump can escape.
Make sure that the intake openings of the pump are not covered when choosing an
installation site.
Using the suction cups at the bottom, the pump can be fastened on any smooth sur-
faces (such as glass, metal).
If the surface is suitable, you can also fix the pump in place by screws. For this pur-
pose, pull out the four legs with the suction cups; then the pump can be mounted via
the holes, one each on the right and on the left side, and suitable screws.
During operation, you may need to use a suitable underlay (e.g. around the
outside of the indoor fountain), so that any water that sprays out cannot
cause any damage to furniture or floors.
To start the pump, plug the mains plug into a mains socket.
The pump will start up immediately after connection.
If little or no water is pumped, there is still some air in the pump. Wait a few seconds,
or unplug the pump briefly and then plug it back in.
When you do this, it is imperative that you
make sure that the power cord forms a
drip loop. This prevents the water from
travelling along the cord toward the sock-
et outlet.
Failure to observe this poses a danger to
life from electric shock!
To pump:
Drip loop