Operating Instructions and Parts List
Pressure Switch (located
internally)- When the compressor
is turned ON, this switch will shut
compressor off automatically when
tank pressure reaches maximum shut-
off / cut-out pressure. If compressor
remains on and air is depleted from
tank, this switch will allow compressor
to automatically restart at the restart /
cut-in pressure.
Introduction (Continued)
Regulator - The regulator controls
the amount of air pressure released at
the hose outlet. Turning the regulator
knob clockwise (to the right) will
increase air pressure at the outlet.
Turning the knob counter-clockwise
(to the left) will lower air pressure to
the outlet. Turning knob fully counter-
clockwise will shut off flow of air
completely.
Pressure Gauges - There are two
gauges located next to the regulator.
These gauges read air pressure in
pounds per square inch (psi) The larger
gauge shows pressure at the outlet.
Make sure this gauge reads ZERO
(by adjusting the regulator) BEFORE
changing air tools or disconnecting
hose from outlet. The small gauge
shows pressure in the tank indicating
compressor is building pressure
properly.
Tank Gauge
ASME Safety Valve
Regulator Gauge
Tank Drain Valve
Figure 3
ASME Safety Valve - This valve
automatically releases air if the tank
pressure exceeds the preset maximum.
Handle - Designed to move the
compressor.
Drain Valve - This valve is located on
the bottom of the tank. Use this valve
to drain moisture from the tank daily
to reduce the risk of corrosion.
Figure 2
Motor Reset - (not shown, located
inside motor). Designed to keep the
motor from overheating. The motor
has a self-hold protector. If the unit
is over worked, a thermal limiter will
shut unit off. If it happens, switch the
unit to the OFF position and unplug
the unit. Wait 30 minutes, plug the
unit in and switch the unit to the
ON position again to resume work.
overload protector which will shut off
motor if it becomes overloaded.
actuated, the motor must be allowed
ON / OFF Switch
Regulator
DC0300, FP2090, FP2091, FP2094 Series
to cool down for approximately 30
minutes before it will reset.
Installation
LOCATION
It is extremely important to use the
compressor in a clean, well ventilated
area where the surrounding air
temperature will not be more than
100°F.
A minimum clearance of 18 inches
between the compressor and a wall
is required because objects could
obstruct air flow.
air inlet near steam, paint spray,
sandblast areas or any other source
of contamination. This debris will
damage the motor.

GROUNDING INSTRUCTIONS

1. This product is for use on a nominal
120 v circuit. It must be grounded. In
the event of an electric short circuit,
grounding reduces the risk of
electrical shock by providing an
escape wire for the electric current.
Unit is equipped with a cord that
This compressor is
has a grounding prong. It will fit
equipped with an
one of the common outlet types
shown in Figure 7. If plug will not fit
If the overload
in the desired outlet, have the plug
protector is
or the outlet replaced by a qualified
electrician.
3
Do not locate the
compressor
Handle
Shroud
Air Outlet
Tank