TYPE
VERSION
ELECTRICAL SPECIFICATIONS
Specifications range
Common specifications
ACCURACY, THE GREATER OF GENERAL AND BASIC VALUES
GENERAL VALUES
Input type
All
BASIC VALUES
Input type
RTD
Lin.R
Volt
TC type: E, J, K, L, N, T, U
TC type: B, R, S, W3, W5, LR
EMC immunity influence
Extended EMC immunity: NAMUR NE 21, A criterion, burst
Effect of supply voltage variation
Vibration
Lloyd's specification no. 1
Max. wire size
Humidity
Dimensions
Tightness (enclosure / terminal)
Weight
ELECTRICAL SPECIFICATIONS, INPUT
RTD AND LINEAR RESISTANCE INPUT
RTD type
Pt 100
Ni 100
Lin. R
4 | 520B7739 | IC.PS.P40.B3.52
Galvanic isolation
Galvanic isolation, EEx
Galvanic isolation
Supply voltage, DC
Galvanic isolation, EEx
Internal consumption
Voltage drop
Isolation voltage, test / operation
Warm-up time
Communications interface
Signal / noise ratio
Response time (programmable)
EEprom error check
Signal dynamics, input
Signal dynamics, output
Calibration temperature
Absolute accuracy
≤ ± 0.05% of span
Basic accuracy
≤ ± 0.2 °C
≤ ± 0.1 Ω
≤ ± 10 μV
≤ ± 1 °C
≤ ± 2 °C
Min. value
-200 °C
850 °C
-60 °C
250 °C
0 Ω
5000 Ω
MBT 9110
084Z7442
084Z7443
MBT 9110, 084Z7442
MBT 9110, 084Z7443
≤ ± 0.01 °C / °C
≤ ± 10 mΩ / °C
≤ ± 1 μV / °C
≤ ± 0.05 °C / °C
≤ ± 0.2 °C / °C
≤ ± 0.5% of span
≤ ± 1% of span
≤ 0,005% of span / VDC
IEC 60068-2-6 Test FC
4 g / 2 – 100 Hz
1 x 1.5 mm
< 95% RH (non-cond.)
ø44 x 20.2 mm
IP68 / IP00
50 g
Max. value
Min. span
25 °C
25 °C
30 Ω
-40 °C – 85 °C
7.2 – 35 V
7.2 – 30 VDC
25 mW – 0.8 W
7.2 VDC
1.5 kVAC / 50 VAC
5 min.
Loop Link
min. 60 dB
1 – 60 s
< 3.5 s
20 bit
16 bit
20 – 28 °C
Temperature coefficient
≤ ± 0.01% of span / °C
Temperature coefficient
stranded wire
2
Standard
IEC 60751
DIN 43760
–
© Danfoss | DCS (im) | 2017.07