The product is in class I and IP65, wich is the protection rate for
•
the units to be used even outdoor. For keeping the protection rate
of the appliance, the connection of the appliance with the power
supply must be done by means of a minimum IP65 system, as per
the standards HD 384 CENELEC for Europe, or international IEC
60346-7-708 1988.
Before pressing the switch, seize firmly the grip and avoid to touch
•
the metal parts.
3. LOCATION
All irradiation heaters are designed to achieve and maintain a certain
thermal comfort to the people who need it both outside and inside. It
is therefore very important to carefully study the area where people
stay and consequently direct the radiation towards them.
The Fiore range of heaters is deliberately designed to be very flexible
in the choice of position. There are three basic options:
A wall mounting bracket version with a specifically designed
•
fitting for wall attachment (768M). Before drilling the holes for
the dowels, be sure that the wall is solid and that you are far from
water tubes or electrical wires. Apply the drilling template on the
wall using adhesive tape and punch in the marked points (see
fig.7). For fixing the appliance at the wall, drill four holes with a
5 mm diameter bit and fix the wall bracket with the dowels and
screws that you find in the box (fig.2). Then fix the appliance to the
wall bracket using the 2 screws and the 2 half rings (fig.2). Check
that the arrows on the wall bracket are turned up.
A chain suspended version (768S). Before drilling the holes for
•
the dowels, be sure that the ceiling is solid and that you are far
from water tubes or electrical wires Fix the buttonhole dowels at
the ceiling at a distance of about 55 cm. Fix the 4 half rings a the
pipe of the appliance, being sure that the chain is fixed with the
screws (fig.3). The 4 half rings should be at the opposite sides of
the pipe, for the best stability. Ensure that the chains are securely
mounted as this application is designed for overhead use.
A version for mounting on upright (768P). The upright must be
•
from 20 up to 60 mm in diameter. For fixing it, please see fig. 4.
13