Battery Inspection/Replacement
Inspect the battery compartment monthly for any signs of degradation. Low battery
voltages will cause inaccuracies in readings. Remove the batteries for storage
or if the meter will not be used for longer than one month. Battery leakage will
compromise the safety of the meter and cause irreparable damage to internal
components.
Shock Hazard. Remove the test leads from the circuit prior to removing the battery
cover. Failure to comply can result in serious injury or death.

Maintenance and Storage

Switch off and disconnect the meter completely before carrying out any
maintenance. Clean the case with a damp cloth and mild detergent. Do not use
abrasives or solvents. Keep away from liquids and ensure the meter is completely
dry before use.

Service and Replacement Parts

• For the 10 Amp Terminal – 11 Amp 1000V AC DC IR30kA Fast Acting Fuse,
10 x 38 mm Ceramic or equivalent
• For the 600 Milli Amp Terminal – 600 Milli Amp 1000V AC DC Fast Acting
Fuse, 6 x 32 mm Ceramic or equivalent
• To ensure the meter is in a safe state of operation, make sure the fuses are
properly seated and that the battery cover is secured to the back of the meter.
With the leads in the terminals but not connected to or touching any voltage
source, turn the function dial to the applicable Amperage setting and verify the
FUSE indicator is NOT displayed. This indicates that the replacement fuse in not
blown or popped. Use only specified replacement fuses.