INSTALLATION
13
AC Wiring Options

Installation Diagrams

WARNING - AC Installations have the potential to cause serious injury or death.
Installations should be performed by an ABYC Certified Electrical Technician to ensure
a safe and trouble free installation.
Depending on the appliances and loads that are intended to be powered by the TruePower Plus
Inverter, there are essentially 2 installation options:
1) TRANSFER TO ALL LOADS – This scenario allows the entire AC panel board to be powered
by the TruePower Plus Inverter. This is the simplest installation for an existing AC panel board.
This scenario enables the user to choose what will be powered by the TruePower Plus Inverter.
Energizing the entire panel may overload the unit depending on the size and the load requested.
The diagram below provided from ABYC found in A-31 battery chargers and inverters
Advantages - Multiple loads from the existing panel board can be chosen, the user is not locked
into set loads. This may require more trial and error to determine which loads the TruePower Plus
Inverter can run.
Ground
Bus/
Engine
Negative
Case Ground/Earth
(Black)
TruePower Plus
Inverter
(Red)
DC
DC Positive Fuse
or Breaker
< 7"
12V Battery
Connection
12V Battery
Circuit
Breaker
Fuse
* Note: Unlike household wiring, the neutral (N) and ground (G) are only connected
together at the SOURCE of power, either inverter or shore/station power. The
TruePower Plus transfer switch maintains this wiring scheme automatically.
INSTALLATION
14
Panel
AC Panel
Ground
Bus
Lights
TV
Coffee Maker
Electric Grill
Microwave
Panel
L
Neutral
AC
G
Bus
OUT
N
L
AC
G
IN
N
Double Pole
AC Main Breaker
Shore/
Station
Power
IN