GENERAL OVERVIEW
7
TruePower Plus Inverter Modes
The TruePower Plus Inverter has 3 distinct modes which allow you to tailor the inverter behavior to
your specific needs:
Pass-through Mode (LCD display is off):
Pass-through mode is indicated by only
being lit on the display panel. All other LEDs are off.
AC
- In pass-through mode up to 30A of shore power can be passed through the inverter.
- In this mode if the shore power is interrupted the inverter will not convert DC to AC to keep the loads on.
- DC draw from the batteries is lowest in this mode (<5 ma); which makes this ideal for long term storage.
Stand-by Mode (LCD display is on)(Output supplied by station power, fast transfer to inverting
when needed):
Stand-by mode is indicated by both
and the LCD display being illuminated on the display panel.
AC
- Power for the loads connected to the inverter comes from shore power.
- In the event of power interruption the inverter will switch automatically to inverting mode to keep
the loads on. This is ideal for loads like computers where a power dropout could cause lost data.
- DC draw from the batteries is <1A in this mode; which may discharge batteries if they do not have
an external source of charge.
Inverting Mode:
Inverting mode is indicated by
12V
and LCD display being illuminated on the display panel.
DC
- Power for the loads is supplied by the attached batteries.
- The unit will automatically switch back to standby mode if AC power becomes present.
TruePower Plus Display Overview
DC to AC Output
Input Power
1
0%
100%
2
4
Check

System Status

Inverting
Output generated from DC
1. DC to AC
The LED graph shows the
Output
percentage of the inverters
total DC to AC conversion
capability (0 to 100%). The
final LED turns red when
the unit is overloaded.
2. Input Power
12V
DC
3. DC Input Level
When the input DC voltage is below 11 VDC, the first
LED is lit red. From 11 to 13 VDC, the LEDs are lit
green and incrementally indicate the battery level.
4. Wrench Symbol
The wrench symbol illuminates red when the
inverter is in fault condition.
5. System Status
The System Status LCD screen shows the status of the
inverter. When the inverter is running normal, the LCD
indicates "SYSTEM NORMAL". If a fault condition occurs,
the LCD screen turns red and display an error message.
6. On / Off button
Pushing the button will change to pass-through mode
On/Off
GENERAL OVERVIEW
DC Input Level
12V
DC
AC
10 VDC
13VDC
On/Off
Inverter Mode
Standby
Pass-through
Output supplied by shore
(fast transfer to batteries
if needed)
Off
Off
AC
AC
Off
Off
Off
Pushing the button
will change to
Standby/Inverting