Is it necessary to exchange the 220-240 V modelling lamp (PROHAL, LUHAL 2 or
LUHAL 3, included in the scope of supply for 220-240 V countries) for a 100-130
V modelling lamp (PACHAL, not included in the scope of supply for 220-240 V
countries) when I travel and go from 220-240 V mains operation to 100-130 V
mains operation?
Technically it is not necessary for the modeling lamp will not take any damage.
Practically we advise to change the modelling lamp in order to assure
a correct rendition of colour. Be sure to also apply pyrex dome PLUSKLA when
using a 100-130 V modelling lamp.
Is it necessary to exchange the 100-130 V modelling lamp (PACHAL, included
in the scope of supply for 100-130 V countries) for a 220-240 V modelling lamp
(PROHAL, LUHAL 2 or LUHAL 3, not included in the scope of supply for 100-130
V countries) when I travel and go from 100-130 V mains operation to 220-240 V
mains operation?
Yes, this is absolutely necessary, otherwise you will damage the 100-130 V
modelling lamp.
Why must I apply pyrex dome PLUSKLA when using 150 W/100-130 V modelling
lamp PACHAL?
100-130 V bulbs with b15 socket do not have a built-in fuse, this is why the
pyrex dome has to be applied to the flash unit. 220-240 V bulbs with b15
socket have a built-in fuse.
Why does the unit doesn't fire when I try to trigger it with the RS 2 radio trigger
or radio remote control (TRIGGER HAPPY/ TRIGGER ONE)?
Check if a receiving channel of the built-in radio trigger is active.
See item 4.
Why does the full control of units doesn't work with the radio remote control
in a multiple-flash setup?
Check if ID's and CH are selected on each unit. Just with individual unit ID's
it is possible to address single units in a multiple-flash set up. See item 7.
(Radio remote control TRIGGER HAPPY) sold seperately)
10
Why does the unit doesn´t fire when I try to trigger it with the MUSEN
infrared trigger?
Check if the "IR/Photo Slave Cell On-Off" button is switched on.
Why does the housing on the right side of the unit (as seen from the control
panel) heats up a bit during stand-by?
An entirely uncritical process. The right side of the unit is where the multivoltage
power supply sits. Determined by the system it gets warm to the
touch during stand-by mode.
Why does the unit sometimes fires a light flash approx. 15 sec after switching it off?
The unit automatically dissipates trigger energy so changing the flash tube
for example can be performed without compunction.
Why does the unit fires sometimes when I turn down the output control to often in
a short period of time?
The unit has to dissipate excess energy every time the output control is being
turned down.
Why can´t I focus my COMSCH umbrella reflector when using it with a Profilux
Plus unit?
Because the housing size of the PROFILITE PLUS units differs from all other
Multiblitz units. Use the PLUSCH umbrella reflector with PROFILITE PLUS units.