6-2. Front Panel Control Descriptions (See Section 6-1)

1
Engine Control Switch
Use switch to start engine, select speed, and
stop engine. In Run/Idle position, engine runs
at idle speed at no load, and weld/power speed
under load. In Run position, engine runs at
weld/power speed.
.
Place switch in Run position to operate
most MIG equipment.
2
Engine Choke Control
Use control to change engine air-fuel mix.
3
Recoil Starter Handle
Use recoil starter handle to start engine if
Engine Control switch does not work.
To Start (Electric): pull out choke and turn En-
gine Control switch to Start position. Release
switch and slowly push choke in when engine
starts.
.
If the engine does not start, let engine
come to a complete stop before attempt-
ing restart.

6-3. Amperage Selection Table For Stick (SMAW) Electrodes

.
Use table to determine the correct control settings for the electrode being used.
Electrode Type
6010
6010
6010
7018
7018
7018
To Start (Recoil): pull out choke and turn En-
gine Control switch to Run or Run/Idle posi-
tion. Pull Recoil Starter Handle until engine
starts. Slowly push choke in when engine
starts.
.
During cold weather, some gasoline en-
gines encounter difficulties that are easily
remedied. See Sections 6-4.
To Stop: turn Engine Control switch to Off
position.
4
Engine Hour Meter/Idle Control
Hour Meter: With engine off, place Engine
Control switch in Run/Idle position to view en-
gine hours.
Oil Change Interval: With engine off, place En-
gine Control switch in the Run position to see
hours before next oil change. Oil hours start at
100 and count down to 0 (zero) (oil change
due).
Electrode Diameter
3/32 in.
1/8 in.
5/32 in.
3/32 in.
1/8 in.
5/32 in.
.
A complete Parts List is available at www.MillerWelds.com
.
Negative hours are shown when engine is
past recommended oil change interval.
.
Change oil after first 20 hours of operation
and then every 100 hours.
To reset, cycle Engine Control switch from
Run/Idle to Run three times within five sec-
onds (engine off).
5
Coarse Range Switch
NOTICE − Do not switch under load.
Use switch to select weld amperage range.
See Section 6-3 for information on amperage
settings for different Stick (SMAW) electrodes.
6
Fine Control
Use control to select weld amperage (Stick/
Tig) within the range selected by the Coarse
Range switch. Control may be adjusted while
welding.
Set control at 10 for maximum generator
power.
Coarse Range Setting
Low 50 − 120
Low 50 − 120
High 70 − 200
Low 50 − 120
High 70 − 200
High 70 − 200
Fine Control Setting
2
9
3
8
3
7
OM-237 711 Page 29