Technical data

NOTICE
Additional technical data and notices on using the device can be found
in the operating instructions.
Operating voltage
Current consumption
(SELV power supply unit)
Power consumption
Light source / Wavelength Laser / 655 nm (visible red light)
Laser class
Impulse duration
Maximum optical output
power (peak)
Scanning rate
Beam exit
Reading distance
Resolution
Code types
Interface type
32
BCL 92
10 ... 30 V DC (SELV)
Peak current during start-
up
30 V: 80 mA
24 V: 100 mA
10 V: 250 mA
2.5 W
1 (acc. to IEC 60825-1:2014)
<120 µs
2.1 mW
600 scans/s
Frontal or lateral
See reading fields
0.165 mm ... 0.5 mm
(6.5 mil ... 20 mil)
2/5 Interleaved
Code 39
Code 128
EAN 128
UPC-A/UPC-E
EAN Addendum
EAN-8/EAN-13
Codabar
Pharmacode (available upon consultation)
Code 32
Code 93
RS 232
BCL 95
4.75 ... 5.5 V DC (SELV)
Max. 450 mA (peak)
Nominal 350 mA at
+5 V DC
1.75 W
0.15 mm ... 0.5 mm
(6 mil ... 20 mil)