Commissioning with factory settings
Ä
Connect the voltage supply:
BCL 92: +10 ... +30 V DC
BCL 95: +5 V DC
Ä
If applicable, connect the switching input and the RS 232 interface.
Ä
Switch on the supply voltage. The status LED must illuminate green.
Ä
Activate the bar code reader via the switching input or with the "+" RS 232
command. The laser switches itself on.
Ä
Hold the following sample bar code up to the bar code reader at a distance of
approx. 100 mm.
Ä
If reading is successful, the laser switches off. The read result is displayed on
the display.
Ä
Deactivate the reading gate by removing the switching input signal or with the
"-" RS 232 command.
LED indicators
LED
Status LED
Decode LED
30
Display
Green, flashing
Green, continuous light
Red, flashing 200 ms
Red, continuous light
Orange, flashing 200 ms
Green, 200 ms on
Red, 200 ms off
Orange, continuous light
Description
Initialization phase
Operational readiness
Warning
Error, no function
Service operation
Reading successful
No reading result
Reading gate active