Tyco BW-PGH PowerG Guide D'installation page 5

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Introduction
The BW-PGH two-way wireless transceiver adds wireless capability to Absoluta Plus/Absoluta 630
alarm controllers, model ABS-18, ABS-48, ABS-128, ABS-128G3 or ABS-630. This manual describes
how to install, program and maintain the BW-PGH.
Controls and Indicators
Status LEDs
The LEDs on the front of the BW-PGH provide feedback regarding the installation, operation and
troubleshooting of the unit. The LEDs function as follows:
Red LED
Module Power Up:
Firmware Update:
Trouble Condition:
Module Confirmation:
PlacementTest:
Green LED
PlacementTest:
Tamper
The BW-PGH has separate built-in wall and case tampers.
Enable or disable the wall tamper by fastening the breakaway wall tamper bracket securely to the wall
using one of the supplied screws.
The case tamper activates when the case is opened and restores when the case is closed. The wall
tamper on the back of the unit is depressed by the mounting surface when properly installed. If the unit
is removed, the tamper activates. Ensure the mounting surface is smooth and free of obstructions that
block access to the rear of the unit. Electrical wires should not run over or under the module when it is
mounted.
Mounting
Note:
Permanently mount the BW-PGH receiver and wireless devices AFTER placement testing each
device.
Find a place that is:
dry,
l
within operating temperature range,
l
central to the proposed placement of all wireless devices,
l
as high as possible. The range is reduced if mounted below ground level,
l
Onsteadyduringmodule power-upsequence thenoff.
Slow flashing = update in progress
Rapid flashing = update failed
No trouble: 1 rapid flash every 10 seconds.
l
If troublesare present,a seriesof flashesoccur every2seconds.
Eachseriesof flashesindicate troublesasfollows:
1 flash: Module not enrolled
l
2 flashes: Loss of contact with module for over 60 seconds
l
3 flashes: Tranceiver Bus low voltage
l
8 flashes: RF interference (jam condition)
l
Flashesrapidlyduringmodule confirmationprocess.
Onsteadywhenlocationisbad.Off whenlocationisgood.
On steady when location is suitable. Off when location is unsuit-
able.
- 5 -