USA / CAN
QCC1 gas regulator
This is a clockwise threaded gas
fitting. Ensure the tank is fully
turned off and screw the regulator
on to the gas tank valve fitting until
tight.
Gas Safety Information
•
The appliance must be installed at least 3.5ft (1 meter) from any flammable materials.
•
The oven should be placed on a non-flammable, stable and flat surface.
•
Make sure your oven is placed in an area that will not be affected by adverse weather.
•
When the diameter of the injector is 1.0mm use the provided 11 WC (28mbar) regulator
with Propane LPG cylinder.
•
An LPG cylinder shall be of a maximum nominal 20 lb (9.1 kg) fuel capacity.
•
Use a suitable provided regulator certified to ANSI Z21.18/CSA 6.3 and a flexiable hose
certified to ANSI Z21.54/CSA 8.4.
•
The regulator shall be installed in such a location that it will not attain a temperature above
130°F (54.5°C)
•
The length of the hose must be no more than 2 ft (61cms). Worn or damaged hose must
be replaced. Ensure that the hose is not obstructed, kinked, or in contact with any part of
the oven other than at its connection.
•
The gas supply hose should be checked periodically and should be replaced if damaged
at least every two years.
•
Check all connections for gas soundness.
•
Your country's national requirements will advise you how often to replace the hose. Regularly
review these requirements for your country.
•
In the case of blocked venturi immediately turn off burner unit, turn off gas supply,
disconnect gas supply and wait until cooled to removed from oven.
•
Ensure the appliance is clear of debris before every use. If any debris does build up use a
brush to remove this when appliance has cooled.
10
POL gas regulator
This is an anticlockwise threaded
gas fitting. Ensure the tank is fully
turned off and screw the regulator
on to the gas tank valve fitting until
tight.
Gas Safety Information
•
The appliance must be installed at least 1 meter from any flammable materials.
•
The oven should be placed on a non-flammable, stable and flat surface.
•
Make sure your oven is placed in an area that will not be affected by adverse weather.
•
When the diameter of the injector is 1.0mm use the provided 28mbar regulator with
Propane LPG cylinder.
•
Appliance only to be used with Propane LPG. Minimum cylinder capacity 4kg maximum
cylinder capacity 13kg.
•
Use a suitable provided regulator certified to AS 4621 and a flexible hose certified to AS/
NZ 1869.
•
The length of the hose must be no more than 1.5 meters. Worn or damaged hose must be
replaced. Ensure that the hose is not obstructed, kinked, or in contact with any part of the
oven other than at its connection.
•
The gas supply hose should be checked periodically and should be replaced if damaged
at least every two years.
•
Check all connections for gas soundness.
•
Your country's national requirements will advise you how often to replace the hose. Regularly
review these requirements for your country.
•
In the case of blocked venturi immediately turn off burner unit, turn off gas supply,
disconnect gas supply and wait until cooled to removed from oven.
•
Ensure the appliance is clear of debris before every use. If any debris does build up use a
brush to remove this when appliance has cooled.
AUS