Important; Connection Diagram - Weka 500.0444.20.01 Instructions De Montage

Masquer les pouces Voir aussi pour 500.0444.20.01:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
Dimensions of the sauna stove:
Length: 280 mm
Depth: 370/460 mm
Height: 460 mm
Anleitung_WEKA_37.461.30.indd 7
Anleitung_WEKA_37.461.30.indd 7
Note:
The control equipment may be destroyed even if it is incorrectly connec-
ted only once. The warranty will be voided if the electrical connection is
not correct.
Instructions for the electrician
DIN VDE 0100 and Accident Prevention Regulation BGV A2 must be observed
for connecting the stove and all electrical systems. An external all-pole
disconnecting device with full isolation according to overvoltage category III
must be installed.

Important:

Mains connection leads must be fl exible cables with polychlorophene sheaths.
No connection leads are supplied with the stove. All the cables installed inside
the cabin must be capable of withstanding temperatures of at least 140 °C.
Heat-resistant silicon cables must be used. The minimum cross-section of
the connection cable and the minimum size of the sauna cabin are shown in
the table (page 5 Table 1). A connection diagram is affi xed to the inside of the
duct cover. Please note that for safety reasons live cables are not allowed to
be routed visibly along the internal walls of the cabin. In prefabricated sauna
cabins the wall element with the air supply opening generally has empty cable
conduits or a duct for routing the cable. If your cabin does not have any cable
routing preparations, we recommend that you install a connection socket
(not supplied) to the outside of the cabin. Drill a hole in the cabin wall near
the cable infeed from the stove and the connection socket. Thread the cable
through the hole to the external connection socket. All cables must be protec-
ted from damage. This can be
Fig. 4
achieved using installation ducting/piping or using wooden covers.

Connection diagram

3.6 kW sauna stove with internal controller
Fig. 4
Fig. 5
Test the insulation resistance
The resistance values between the various conductor terminals and the case
(protective earth) can be measured using an insulation resistance measuring
unit. The total insulation resistance between the conductor terminals and case
(protective earth) must defi nitely be greater than 1 MOhm.
GB
7
10.04.19 21:27
10.04.19 21:27

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

37.461.30

Table des Matières