3.4 Input mode

3.5 Multiplying factor
3.6 Dividing factor
3.7 Decimal point
Quadrature input
INP A: count input 0°
INP B: count input 90°
Quadrature input with
pulse doubling
INP A: count input 0°
INP B: count input 90°
Each pulse edge of INP A
will be counted
Quadrature input with
pulse quadrupling
INP A: count input 0°
INP B: count input 90°
Each pulse edge of INP A
and INP B will be count-
ed.
It can be set from 00.0001
up to 99.9999.
The decimal point is set to
4 decimal places.
„0" is not accepted!
It can be set from 00.0001
up to 99.9999.
The decimal point is set to
4 decimal places.
„0" is not accepted!
The decimal point defines
the way of displaying the
count values. It does not
affect counting.
0
no decimal place
0.0 one decimal place
0.00 two decimal places
0.000 three decimal places
3.8 SET/RESET Mode
3.9 SET value
For programming the decimal point see 4.6

3.10 End of programming

manual reset via the red
SET/RESET key and
electrical reset via the
SET/RESET input
no reset (red SET/RESET
key and SET/RESET
input locked)
only electrical reset via
the SET/RESET input
only manual reset via
the red SET/RESET key
The device will be set to
the set point by pressing
the red SET/RESET key
or activating the
SET/RESET input.
SET value -199999...
999999 (number of deci-
mal places depends on
the decimal point option)
The programming routine
is repeated once more.
The values set until now
can be checked and modi-
fied.
The programming routine
wil be left and all values
set will be stored as new
parameters.
Afterwards the device is
ready for operation.
3