4.3 Programming lock

Programming access depends on the selected input configuration.
1. Voltage 20 or 200 V: Press
Enter 0 or 1 in line„LC".
2. All other input configurations provide access rights at the end of
display configuration as follows:
After parameterization of „dSP2" press
Enter 0 or 1 in line „LC".
Programming lock disabled
Programming lock enabled
Programming lock means programming lines are read only which will
be signaled by [dAtA] instead of [Pro] appearing in the display when
accessing programming level.

5 Technical data

Technical data - electrical ratings
Voltage supply
Power consumption
Display
Number of digits
Digit height
Display range
Display refresh
A/D transformer
Analog input
Programmable
parameters
Data memory
Standard
DIN EN 61010-1
Emitted interference
Interference immunity
www.baumer.com
and hold for 5.
and hold for 5 s.
21...53 VAC (50/60 Hz) or
10.5...70 VDC
85...265 VAC (50/60 Hz) or
100...300 VDC
1.8 W
LED, 7-segment display (with 60 unit
stickers for front)
4-digits
10 mm
-1999...9999 („OuE" to signal
overflow)
250 ms
Principle ∑∆
Resolution 16 bit
Measuring rate 20/s
Measuring accuracy ±(0.1 % +3 digit)
Temp. coeffic. 100 ppm/°C
Current or voltage input
Measuring range
Display range can be linearised
Decimal point
>10 Jahre in EEPROM
Protection class II
Overvoltage category II
Pollution degree 2
DIN EN 61000-6-3
DIN EN 61000-6-2
PA200