The BELFOX Ultra VA / 800 / 800i actuator requires a concrete foundation or a
steel construction of at least 400 x 200 mm, each at a frost-free depth (in Ger-
many = min. 80 cm deep).
Make the foundations sufficiently large so that the material does not break out
when drilling the mounting holes. For the required dimensions, refer to the
manufacturer's dimensional specifications .
The foundation or console should be slightly higher than the surrounding level.
To avoid ice surfaces in winter, water should be able to run away from the run-
ning track with a gradient.
(H x B x T) 328 mm x 395 mm x 217 mm (incl. drive pinion)
Height upper edge of drive pinion
: 125 – 280 mm
Height of the magnetic limit switches : 135 – 290 mm
208
35
69
17,5
Lay the power supply line (230 V) through an empty pipe in the foundation. Lay
the connection lines (24 V) for accessories through another empty conduit,
which is separated from the mains supply line.