WallMaster chassis installation instructions

for WS, WE and WY models
CAUTION
Excessive Weight Hazard
Use two or more people when installing
your air conditioner.
Failure to do so can result in back or
other injury.
CAUTION
Cut/Sever
Although great care has been taken to
minimize sharp edges in the construction
of your unit, use gloves or other hand
protection when handling unit.
Failure to do so can result in minor to
moderate personal injury.
Figure 7
10
Check the sleeve to be certain it has been correctly
STEP 1
installed in the wall. Remove the front panel on the
WSE SLEEVE. Remove the rear WEATHER PANEL.
Reverse grille. Place lower edge into sleeve tab
(Friedrich logo facing out). Align slots with the screw
holes. Secure grille with screws.
Check the anchor screw. There should
A.
be four (4) in the WSE SLEEVE (two in
each side.)
Determine if the sleeve has a downward
B.
slope of 3/8" to the outside. See page 8
for futher details.
Check to be sure the sleeve has been
C.
sealed around all edges with an industrial
type caulking on both the outside and
inside to prevent rain entry.
STEP 2
Check the electrical receptacle to see that it conforms
to the requirements for the chassis model to be
installed. See page 3, for the receptacle
requirements.
STEP 3
Remove the chassis from the shipping carton. Lift
the chassis by the basepan and slide it into the
front of the
sleeve.
Push the chassis all the way into the sleeve, using
the plastic front handles, so that the front panel
meets the front edge of the shell.
NOTE: Chassis comes with pre-installed seal gasket.
(Obtain assistance as needed)