Technical Data

Rain water tank pump
Art. No
Service connection
Rated input
Max. immersion
Max. delivered quantity
Max. head of delivery
Max. suction
Max. Water temperature
Rain water tank pump Service con-
nection
Degree of protection
Weight
Read and understand the operating
instructions before using the appliance. Familiarise
with the control elements and how to use the
appliance properly. Abide by all the safety measures
stated in the service manual. Act responsibly toward
third parties.
The operator is responsible for accidents or risks to
third parties.
In case of any doubts about connection and operati-
on refer please to our customer center
This appliance can be used by child-
ren aged from 8 years and above
and persons with reduced physical,
sensory or mental capabilities or
lack of experience and knowledge
if they have been given supervision
or instruction concerning use of
the appliance in a safe way and un-
derstand the hazards involved.
Children shall not play with the
appliance.
Cleaning and user maintenance
shall not be made by children wit-
hout supervision.

Specified Conditions Of Use

The pump is solely used for drainage and for pum-
ping into and out of containers in the house, garden,
farm and agriculture and only for water. Respecting
technical data and safety precautions.
Do not use this product in any other way as stated
for normal use. Not observing general regulations
in force and instructions from this manual does not
make the manufacturer liable for damages.
GFP 5200
Do not use pump at outside temperatures over 40 °C
or under 0 °C
94617
230 V~50Hz
The pump is not suited for long-run operation
(e.g. as a circulation pump in ponds or streams).
350 W
When used in this manner, its service life is curtailed
7 m
correspondingly. In these cases, then, use a time
switch to secure sufficient idle periods between
5200 l/h
cycles of operation.
11 m
Do not leave the pump unattended while in
3 mm
operation in order to prevent subsequent
35 °C
damages caused by eventual malfunctions. Make
sure to disconnect the device from the grid if you
3/4" AG
do not plan on using it.
IPX8
Do not use the pump for drinking water!
4,1 kg
The pump must not be used to pump waste
water.

Emergency procedure

Conduct a first-aid procedure adequate to the injury
and summon qualified medical attendance as quickly
as possible. Protect the injured person from further
harm and calm them down. If you seek help, state the
following pieces of information: 1. Accident site, 2.
Accident type, 3. Number of injured persons, 4. Injury
type(s)
Symbols
WARNING/CAUTION!
WARNING - Read the operating instruc-
tions to reduce the risk of injury.
Unplug the machine before any work
on it.
Cable pulling / transport prohibited
Staying in the transportation medium
prohibited
Warning against dangerous electric
voltage
Any damaged or disposed electric or
electronic devices must be delivered to
appropriate collection centres.
CE marking