Building Air Conditioning Control System
System Remote Controller
Installation Manual
This manual describes only installation for the centralized controller (System Remote Controller PAC-SF41SCA), capable
of controlling up to 50 air-conditioning or Lossnay units (max. 32 groups). For information about how to wire and how to
install air conditioning units, see the installation manual for them.
For your safety, first be sure to read
Controller PAC-SF41SCA correctly.
1
Safety Precautions
The following two symbols are used to denote dangers that may be caused by incorrect use and their degree:
WARNING
This symbol denotes what could lead to serious injury or death if you misuse the PAC-SF41SCA.
This symbol denotes what could lead to a personal injury or damage to your property if you misuse
CAUTION
the PAC-SF41SCA.
After reading this installation manual, keep it in a place where the final user can see it anytime he or she wants to it.
When someone moves, repairs or uses the PAC-SF41SCA, make sure that this manual is forwarded to the final user.
Ask your dealer or technical representative to install the
unit.
Any deficiency caused by your own installation may result in
an electric shock or fire.
Install in a place which is strong enough to withstand
the weight of the PAC-SF41SCA.
Any lack of strength may cause the PAC-SF41SCA to fall
down, resulting in personal injury.
Firmly connect the wiring using the specified cables.
Carefully check that the cables do not exert any force
on the terminals.
Improper wiring connections may produce heat and possi-
bly a fire.
Never modify or repair the PAC-SF41SCA by yourself.
Any deficiency caused by your modification or repair may
result in an electric shock or fire.
Consult with your dealer about repairs.
Do not install in any place exposed to flammable gas
leakage.
Flammable gases accumulated around the body of PAC-
SF41SCA may cause an explosion.
Do not use in any special environment.
Using in any place exposed to oil (including machine oil),
steam and sulfuric gas may deteriorate the performance sig-
nificantly or give damage to the component parts.
Wire so that it does not receive any tension.
Tension may cause wire breakage, heating or fire.
Completely seal the wire lead-in port with putty etc.
Any dew, moisture, insects entering the unit may cause an
electric shock or a malfunction.
Do not wash with water.
Doing so may cause an electric shock or a malfunction.
Do not install in any place at a temperature of more than
40°C or less than 0°C or exposed to direct sunlight.
Do not install in any steamy place such a bathroom or
kitchen.
Avoid any place where moisture is condensed into dew. Doing
so may cause an electric shock or a malfunction.
" 1 Safety Precautions "
described below thoroughly and then install the System Remote
WARNING
CAUTION
PAC-SF41SCA
Ensure that installation work is done correctly follow-
ing this installation manual.
Any deficiency caused by installation may result in an elec-
tric shock or fire.
All electrical work must be performed by a licensed tech-
nician, according to local regulations and the instruc-
tions given in this manual.
Any lack of electric circuit or any deficiency caused by in-
stallation may result in an electric shock or fire.
Do not move and re-install the PAC-SF41SCA yourself.
Any deficiency caused by installation may result in an elec-
tric shock or fire.
Ask your distributor or special vendor for moving and instal-
lation.
To dispose of this product, consult your dealer.
Do not install in any place where acidic or alkaline solu-
tion or special spray are often used.
Doing so may cause an electric shock or malfunction.
Use standard wires in compliance with the current ca-
pacity.
A failure to this may result in an electric leakage, heating or
fire.
Do not touch any PCB (Printed Circuit Board) with your
hands or with tools. Do not allow dust to collect on the
PCB.
Doing so may cause fire or an electric shock.
Do not remove the insulation sheet on the PCB.
Doing so may cause an electric shock.
Do not touch any control button with your wet hands.
Doing so may cause an electric shock or a malfunction.
Do not press any control button using a sharp object.
Doing so may cause an electric shock or a malfunction.
Never contact the power supply with the control wiring
terminals.
Doing so will certainly cause the controller to catch fire.

Publicité

Table des Matières
loading

Sommaire des Matières pour Mitsubishi Electric PAC-SF41SCA

  • Page 1 After reading this installation manual, keep it in a place where the final user can see it anytime he or she wants to it. When someone moves, repairs or uses the PAC-SF41SCA, make sure that this manual is forwarded to the final user.
  • Page 2: Table Des Matières

    Confirming the Supplied Parts Check that the box contains the following parts in addition to this manual: (1) System remote controller (with upper and lower case) ..................1 (2) Cross recessed pan head screws (M4×30) ......................2 (3) Wood screws (4.1×16, for directly hooking to the wall) ..................2 (4) Room label ................................
  • Page 3: System Configuration

    System Configuration Central management transmission line Indoor unit Outdoor unit Indoor and outdoor transmission line M-NET remote controller Interlocked operation with ventilation unit System remote controller Ventilation unit [059] [012] [011] [010] [009] [015] [014] [013] [113] [112] [110] Group 13 Group 12 Group 11 Group 10...
  • Page 4: How To Install

    How To Install (1) Choose a location in which to install the system remote controller (switch box) in accordance with the following requirements: External size of Extra space around 1 The space as shown in the diagram at right is required remote controller remote controller whether the controller is installed on the wall or in the...
  • Page 5 (4) Set the system remote controller address with the rotary switches. Rotary switch × 10 × 1 Example : Address 208 System remote controller upper case CAUTION Addresses between 201 and 250 may be set with the system remote controller. The place of 100 is fixed to “2”.
  • Page 6 To remove the upper case, insert a minus screwdriver into one of the open slots and move it in the direction of the arrow as shown in the diagram at right. CAUTION Do not turn the screwdriver while it is inserted into the open slot.
  • Page 7: Instruction Book

    Connecting Optional parts Connector CN2 (1) Program timer • When connecting a program timer connect a 5-core cable to connector CN2 (timer connector) on the upper case (a 5-core cable is supplied with Thin-wall portion the program timer). • Cut out the thin-wall portion to take the cable. •...
  • Page 8: Système De Contrôle De Climatiseur Pour Bâtiments

    PAC-SF41SCA Manuel d’installation Le présent manuel décrit uniquement l’installation du contrôleur centralisé (télécommande du système PAC-SF41SCA), capable de contrôler jusqu’à 50 climatiseurs ou unités Lossnay (max. 32 groupes). Pour toute information concernant le câblage et l’installation des climatiseurs, consulter leurs manuels d’installation respectifs.
  • Page 9 Contrôler les pièces fournies Assurez-vous que la boîte contient les pièces suivantes en plus de ce manuel : (1) Commande à distance du système (avec les boîtiers supérieur et inférieur) ..............1 (2) Vis à tête cylindrique bombée à empreinte cruciforme (M4 × 30) .................. 2 (3) Vis en bois (4,1 ×...
  • Page 10: Configuration Du Système

    Configuration du système Ligne de transmission de la gestion centralisée Appareil Appareil Télécommande M-NET Ligne de transmission entre l’intérieur et l’extérieur extérieur intérieur Fonctionnement interverrouillé avec le dispositif de ventilation Commande à dis- Dispositif de tance du système ventilation [059] [012] [011] [010]...
  • Page 11: Comment Installer L'appareil

    Comment installer l’appareil (1) Choisissez un emplacement pour l’installation de la télécommande (boîte de distribution) en tenant compte des exigences suivantes : Dimension Espace supplémentaire extérieure de la 1 L’espace indiqué sur le schéma de droite est nécessaire, que autour de la télécommande télécommande le contrôleur soit installé...
  • Page 12: Lors D'une Utilisation Conjointe Avec Le Contrôleur Du Système Principal (Contrôleur Central), Régler

    (4) Régler l’adresse de la télécommande du système à l’aide des commutateurs rotatifs. Commutateur rotatif Exemple : Adresse 208 Boîtier supérieur de la télécommande du système. ATTENTION Vous disposez des nombres compris entre 201 et 250 pour définir l’adresse de la télécom- mande de réseau.
  • Page 13: Lors De L'utilisation D'une Boîte De Distribution

    (7) Mettre le boîtier supérieur en place. Accrochez tout d’abord le boîtier supérieur aux deux atta- ches supérieures puis mettez-le en place de la manière illus- trée à droite. ATTENTION • Appuyez sur le boîtier jusqu’à ce qu’il se ferme avec un bruit sec.
  • Page 14: Comment Connecter Les Pièces Optionnelles

    Comment connecter les pièces optionnelles (1) Programmateur • Lorsque vous branchez un programmateur, raccordez un câble à 5 âmes Connecteur CN2 au connecteur CN2 (connecteur du programmateur) situé sur le boîtier supérieur. (Un câble à 5 âmes est fourni avec le programmateur). •...

Table des Matières