Temperature Measurement - Kübler Codix 534 Instructions D'utilisation

Afficheur numérique à entrées analogiques
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

6. Technical data
Display:
Measuring ranges: 0...10 VDC
Resolution:
Accuracy:
Null balancing:
Temperature drift: < 70 ppm/K
Measuring time:
Current measurement:
Voltage measurement:
Voltage supply:
Current consumption: max. 50 mA
Ambient temperature: -20 °C...+65 °C
Storage temperature: -25 °C...+70 °C
Data backup:
Weight:
Vibration resistance:
Shock resistance: EN 60068-2-27
Protection level:
EMC:
UL-Certification
Error messages:
Err 0*
Error/failure in the A/D section
Err 1** Invalid value (during programming)
Err 2** Lo-value > Hi-value
(during programming)
Err 3*
Error/failure in FRAM
Page 7 (R60046.0009 - Index 1)
5-digit 7-segment LED
display, height 8 mm
2...10 VDC
0...20 mA DC
4...20 mA DC
14 bits
0.1% ± 1 digit over the
whole measuring range at
20°C
automatic
0.1 sec/0.5 sec
voltage drop:
max. 2.0 V DC
current limitation: 50 mA
input resistance: > 1 MΩ
max. input voltage: 30 VDC
10...30 V DC,
galvanically isolated
external fuse T 0.1 A
EEPROM
1 million storage cycles
or 10 years
approx. 50 g
EN 60068-2-6
10...55 Hz/1 mm/30 min
100 G: 2 ms
10 G: 6 ms
IP65 (front side)
EN 55011 Class B,
EN 61000-6-2,
EN 61000-6-3,
EN 61326-1
File E128604
Err 4** Analog input signal exceeds the
valid measuring range
Err 5*
Error/failure in FRAM. Device null
balancing not performed
*
Please send device back for inspection
**
Check input signal and programming
7. Scope of the delivery
– Digital display
– Mounting clip
– Front bezel for screw fastening
cut-out 50x25 mm
– Front bezel for mounting clip fastening
cut-out 50x25 mm
– Seal
– 1 sheet of adhesive symbols
8. Examples

8.1 Temperature measurement

A temperature sensor with linear characte-
ristics (in case of non-linear sensors, install
linearizing components upstream) delivers 0 V
at -10°C and 10 V at 80°C. The selected mea-
suring range is 0...10 V. 0 V is the smallest
measured value possible. The display value
-10 is now assigned to this measured value.
Accordingly, 10 V is the largest measured
value. The display value 80 is assigned to this
measured value. The display is now set for the
sensor and can display any intermediate value.
Display value freely positionable
within the measuring range

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

6.534.012.300

Table des Matières