Page 6
ENGLISH
STEP 5. Connect the Cleaner
1. Attach the flow regulator valve (e) to the leader
hose (h). Leader hose is the hose section with
foam float pre-attached (Figure 6).
2. Submerge the hose and flood with water (no
bubbles visible).
3. Submerge the cleaner and flood with water (no
bubbles visible).
4. Connect the hose to the cleaner head by pushing
the flow regulator valve (e) onto the cleaner
(Figure 7).
5. Allow the cleaner to sink to the bottom of the pool.
6. Turn on the pool filter pump.
STEP 6. Test for Proper Flow
To avoid serious injury, make sure to turn off the suction pump that is responsible for the pool cleaner
operation. Do not expose your hair, loose clothing, jewelry, etc. to the open end of the hose.
The flow regulator valve is designed to consistently limit high flow of water through the cleaner. When flow is
correct, the cleaner components are less susceptible to damage and the life of the cleaner can be extended.
Wheel rotation speed is a good indicator of how water is flowing through the cleaner. By checking for proper
wheel rotation timing, you can verify the cleaner is operating at maximum efficiency.
Time wheel rotations:
1. Turn on the pool filter pump.
2. Obtain a stopwatch or timer.
3. Leaving the pump on and water flowing through the
cleaner, bring the cleaner to the surface of the water
and hold it fully submerged just below the water line.
4. Locate the yellow wheel speed indicator on the
rear right wheel (Figure 8).
|
Zodiac
MX Pool Cleaner
Owner's Manual
®
h
MX8
WARNING
cleaner shown
Figure 8
e
Figure 6
h
e
a
Figure 7