GARANT Workbench with electric height adjustment
Error code
en
E097
E101
E102
E103
E104
E105
E106
E150
E151
E152
E153
E154
E200
E201
E202
E203
E204
E205
E206
58
Possible cause
DC output: Discharge
current too high
AC current measure-
ment error
DC current measure-
ment error
Power supply unit start
error
Power supply unit short
circuit
High voltage fault
Fault in the power sup-
ply control circuit
230 V-AC output over-
load
230 V-AC peak input
surge current duration
too long
230 V-AC peak input
surge current value too
high
PE/N relay fault
Charging current too
high
High voltage fault
230 V-AC output over-
load
Transfer relay fault
High voltage
Overvoltage
Action
Disconnect the current
source or regulate it.
12 V-DC output load draw-
ing too much current. Dis-
connect the spindle lift sys-
tem from the battery.
Restart the battery.
Restart the battery.
If the fault still persists.
Output is overloaded.
Reduce the load on the 230
V-AC.
Reduce the load on the 230
V-AC.
Reduce the load on the 230
V-AC.
Restart the battery.
If the fault still persists.
Restart the battery.
Instruction manual
Performed by
Trained person
Hoffmann Group Customer
Service, electrician
Hoffmann Group Customer
Service, electrician
Trained person
Hoffmann Group Customer
Service
Hoffmann Group Customer
Service
Electrician
Electrician
Electrician
Hoffmann Group Customer
Service
Hoffmann Group Customer
Service
Trained person, Hoffmann
Group Customer Service
Hoffmann Group Customer
Service
Hoffmann Group Customer
Service
Trained person, Hoffmann
Group Customer Service