Welcome Display Text
The AD-500 display will show a visitor a welcome message alternating with
instructions on how to call a resident. The welcome message can be customized
to suit the installation.
! NOTE: When changing the welcome display, programming the AD-500
from a computer is the preferred method. Refer to the "Programming from
the Local Keypad" section of these instructions for details on alphanumeric
entry from the keypad.
1. If not already in Programming Mode, use the local keypad to enter the
master password and access programming.
2. Press:
3. Enter the new text for the top line of the display (up to 16 characters).
4. Press:
5. Enter the new text for the bottom line of the display (up to 16 character).
6. Press:
7. Exit Programming Mode if all programming is complete.

Automatic Telephone Answer

The factory setting will allow the system to detect a ring signal on the telephone
line and answer the call. The automatic answer feature can be turned off,
although remote programming and remote control of the system will no longer
be possible.
1. If not already in Programming Mode, connect by telephone or use the
local keypad. Enter the master password and access programming.
2. Press:
3. Select the option for automatic telephone answering:
• Enter 0 to turn OFF the automatic telephone answering.
• Enter 1 to turn ON the automatic telephone answering.
4. Press:
5. Exit Programming Mode if all programming is complete.

Speaker Chirp on Keystrokes

The factory setting will not cause the speaker chirp when each key on the local
keypad is pressed. The speaker chirp can be turned off.
1. If not already in Programming Mode, connect by telephone or use the
local keypad. Enter the master password and access programming.
2. Press:
3. Select the option for keystroke speaker chirps:
• Enter 0 to turn OFF the keystroke speaker chirps.
• Enter 1 to turn ON the keystroke speaker chirps.
4. Press:
5. Exit Programming Mode if all programming is complete.

Speaker Tone on Relay Channel "A" Activation

The factory setting will not cause the speaker to sound a tone when access is
granted with Relay Channel "A". The tone can be turned on if desired.
1. If not already in Programming Mode, connect by telephone or use the
local keypad. Enter the master password and access programming.
2. Press:
3. Select the option for relay activation tone:
• Enter 0 to turn OFF the relay activation tone.
• Enter 1 to turn ON the relay activation tone.
4. Press:
5. Exit Programming Mode if all programming is complete.

Maximum Visitor Talk Time

Visitors will converse with residents over the telephone until the resident grants
or denies access. If the resident responds to the visitor's request by pressing
their telephone keys the system will hang up and release the telephone line. If for
some reason the resident does not press the telephone keys or does not hang
up, the system will automatically disconnect the visitor after 60 seconds. The
resident can extend the talk time by pressing the # key on their telephone. The
disconnect time can be adjusted from 15-255 seconds.