Publicité

Liens rapides

OM-265 461B
2015-03
Processes
Multiprocess Welding
Description
Accessory
FieldPro Remote
CE
File: Multiprocess
Visit our website at
www.MillerWelds.com

Publicité

Table des Matières
loading

Sommaire des Matières pour Miller FieldPro Remote

  • Page 1 OM-265 461B 2015-03 Processes Multiprocess Welding Description Accessory FieldPro Remote ™ File: Multiprocess Visit our website at www.MillerWelds.com...
  • Page 2 We know you don’t have time to do it any other way. That’s why when Niels Miller first started building arc welders in 1929, he made sure his products offered long-lasting value and superior quality.
  • Page 3: Table Des Matières

    TABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING ....... . . 1-1.
  • Page 4 DECLARATION OF CONFORMITY for European Community (CE marked) products. MILLER Electric Mfg. Co., 1635 Spencer Street, Appleton, WI 54914 U.S.A. declares that the product(s) identified in this declaration conform to the essential requirements and provisions of the stated Council Directive(s) and Standard(s).
  • Page 6: Section 1 − Safety Precautions - Read Before Using

    SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som 2013−09 Protect yourself and others from injury — read, follow, and save these important safety precautions and operating instructions. 1-1. Symbol Usage DANGER! − Indicates a hazardous situation which, if Indicates special instructions.
  • Page 7 D Remove stick electrode from holder or cut off welding wire at FUMES AND GASES can be hazardous. contact tip when not in use. D Wear body protection made from durable, flame−resistant material Welding produces fumes and gases. Breathing (leather, heavy cotton, wool). Body protection includes oil-free these fumes and gases can be hazardous to your clothing such as leather gloves, heavy shirt, cuffless trousers, high health.
  • Page 8: Additional Symbols For Installation, Operation, And Maintenance

    1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. MOVING PARTS can injure. D Do not install or place unit on, over, or near D Keep away from moving parts such as fans. combustible surfaces. D Keep all doors, panels, covers, and guards D Do not install unit near flammables.
  • Page 9: California Proposition 65 Warnings

    1-4. California Proposition 65 Warnings Welding or cutting equipment produces fumes or gases This product contains chemicals, including lead, known to which contain chemicals known to the State of California to the state of California to cause cancer, birth defects, or other cause birth defects and, in some cases, cancer.
  • Page 10: Section 2 − Consignes De Sécurité − Lire Avant Utilisation

    SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATION fre_som_2013−09 Pour écarter les risques de blessure pour vous−même et pour autrui — lire, appliquer et ranger en lieu sûr ces consignes relatives aux précautions de sécurité et au mode opératoire. 2-1.
  • Page 11 D Ne pas raccorder plus d’une électrode ou plus d’un câble de D Avoir recours à des écrans protecteurs ou à des rideaux pour masse à une même borne de sortie de soudage. Débrancher le protéger les autres contre les rayonnements les éblouissements câble pour le procédé...
  • Page 12: Dangers Supplémentaires En Relation Avec L'installation, Le Fonctionnement Et La Maintenance

    LES BOUTEILLES peuvent exploser DES PIECES DE METAL ou DES si elles sont endommagées. SALETES peuvent provoquer des blessures dans les yeux. Les bouteilles de gaz comprimé contiennent du gaz sous haute pression. Si une bouteille est D Le soudage, l’écaillement, le passage de la endommagée, elle peut exploser.
  • Page 13 LES CHARGES ÉLECTROSTATI- RAYONNEMENT HAUTE QUES peuvent endommager les cir- FRÉQUENCE (H.F.) risque cuits imprimés. provoquer des interférences. D Établir la connexion avec la barrette de terre D Le rayonnement haute fréquence (H.F.) peut avant de manipuler des cartes ou des pièces. provoquer des interférences avec les équi- pements de radio−navigation et de com- D Utiliser des pochettes et des boîtes antista-...
  • Page 14: Proposition Californienne 65 Avertissements

    2-4. Proposition californienne 65 Avertissements Les équipements de soudage et de coupage produisent des Ce produit contient des produits chimiques, notamment du fumées et des gaz qui contiennent des produits chimiques plomb, dont l’État de Californie reconnaît qu’ils provoquent dont l’État de Californie reconnaît qu’ils provoquent des mal- des cancers, des malformations congénitales ou d’autres formations congénitales et, dans certains cas, des cancers.
  • Page 15: Section 3 − Definitions

    SECTION 3 − DEFINITIONS 3-1. Additional Safety Symbols And Definitions Some symbols are found only on CE products. Warning! Watch Out! There are possible hazards as shown by the symbols. Safe1 2012−05 Do not discard product (where applicable) with general waste. Reuse or recycle Waste Electrical and Electronic Equipment (WEEE) by disposing at a designated collection facility.
  • Page 16: Section 4 − Specifications

    SECTION 4 − SPECIFICATIONS 4-1. Dimensions And Weight Remote 9.75 in. 11.6 in. 9.08 lb (4.12 kg) (247.7 mm) (294.6 mm) 4.6 in. 116.8 mm) 18 in. (457.2 mm) 18 in. (457.2 mm) Ref. 255 429-B 4-2. Environmental Specifications A. IP Rating IP Rating IP23 This equipment is designed for outdoor use.
  • Page 17: Section 5 − Operation

    Electrical Tape Or Heat Shrink The work sense lead is required for op- Tubing Once terminal or wire is on post, tighten eration of the FieldPro Remote. If ring terminal is cut or broken, the bare wing nut. Lead wire can be looped around the post and Ring Terminal 1/2 in.
  • Page 18: Connecting To Power Source

    255 420-B Electrode Holder of the work sense lead to the binding post The FieldPro Remote can only be on the side of the FieldPro Remote. Work Cable used with FieldPro power sources. See welding power source Owner’s Connect work cable to WORK (bottom)
  • Page 19: Remote Interface Operation Description

    DCEN mode can be used for EXX10 and/or EXX18 process setting. The mode has to be set for each electrode process individually. NOTICE − Controls on the FieldPro Remote are NOT adjustable during welding. To make adjustments during welding, use the power source controls. Adjustments can be made if using the RHC-14 remote or wireless remote.
  • Page 20: Routine Maintenance

    5-6. Routine Maintenance Disconnect power before maintaining. n = Check ~ = Clean l = Replace Every Months l Unreadable Labels ~ Weld Connections n Tighten Weld Connections nl Weld Cables And Cords 5-7. Remote Diagnostics Help Codes Display Example Display Code Fault Description...
  • Page 21 Display Code Fault Description PC2 Power Supply Low Indicates the control supply on PC2 is malfunctioning. If this code appears on the display, contact the nearest Factory Authorized Service Agent. Primary Input Line Voltage Malfunction Indicates input primary line voltage is too low or power source is incorrectly linked.
  • Page 22: Section 6 − Electrical Diagrams

    SECTION 6 − ELECTRICAL DIAGRAMS 255 132-B Figure 6-1. Circuit Diagram OM-265 461 Page 17...
  • Page 23: Section 7 − Parts List

    A complete Parts List is available at www.MillerWelds.com SECTION 7 − PARTS LIST Hardware is common and not available unless listed. 255 407-C Figure 7-1. Remote Parts Assembly Item Dia. Part Quantity Mkgs. Description Figure 7-1. Remote Parts Assembly ..
  • Page 24 Notes...
  • Page 25 Notes...
  • Page 26 Notes...
  • Page 27 Effective January 1, 2015 (Equipment with a serial number preface of MF or newer) This limited warranty supersedes all previous Miller warranties and is exclusive with no other guarantees or warranties expressed or implied. Warranty Questions? LIMITED WARRANTY − Subject to the terms and conditions below, 6 Months —...
  • Page 28: For Service

    Contact the Delivering Carrier to: File a claim for loss or damage during shipment. For assistance in filing or settling claims, contact your distributor and/or equipment manufacturer’s Transportation Department. © ORIGINAL INSTRUCTIONS − PRINTED IN USA 2015 Miller Electric Mfg. Co. 2015−01...

Table des Matières