Notes:
The device can produce continuous haze without reheating. When the interval between outputs comes to an
end, the device starts producing haze immediately.
The timer settings are saved in the internal memory. The next time you plug in the device and press
<TIMER>, it will start in timer-controlled mode with the settings as specified for the previous use.
Continuous Mode
1. Connect nothing to the DMX input [15] of the device.
2. Press <VOLUME> to start continuous operation.
3. To stop continuous operation, press <MANUAL>.
Note: The device can produce continuous haze without reheating. Each time you press <VOLUME>, the device
starts producing haze immediately.
Manual Mode
1. Connect nothing to the DMX input [15] of the device.
2. Press and hold <MANUAL>. The device starts producing haze.
3. Release the <MANUAL> button to stop.
Setting the Fan Speed
1. Press <FUNCTION> until <FAN SPEED> is displayed.
2. Use <UP> and <DOWN> to set the fan speed (0 ~ 10).
7.4
DMX Mode
This mode allows you to control the device by any universal DMX controller.
All DMX-controlled devices need a digital start address so that the correct device responds to the signals.
This digital start address is the channel number from which the device starts to "listen" to the DMX
controller. The same starting address can be used for a whole group of devices or an individual address can
be set for every device.
When all devices have the same address, all the units will "listen" to the control signal on one particular
channel. In other words: changing the settings of one channel will affect all devices simultaneously. If you
set individual addresses, each device will "listen" to a separate channel number. Changing the settings of
one channel will only affect the device in question.
In case of the 2-channel mode, you will have to set the start address of the first unit to 1 (CH1~2), the
second to 3 (1 + 2) (CH3~4), the third to 5 (3 + 2) (CH5~6), and so on. The highest start address is 511.
To set the device to work with a DMX controller:
1. Press <FUNCTION> until <DMX 512 ADD> is displayed.
2. Use <UP> and <DOWN> to set the DMX starting address (001 ~ 512).
DMX Channel Values
Channel
From
1
0
2
0
8.
Cleaning and Maintenance
This device features an automatic heater cleaning function. After use, wait for 3 minutes before switching
off the power to let the machine complete the cleaning process.
Disconnect the device from the mains prior to maintenance activities. Let the device cool down.
All screws should be tightened and free of corrosion.
The housing, visible parts, the mounting supports and the installation location should not be deformed,
modified or tampered with; e.g. do not drill extra holes in mounting supports, do not change the location of
the connections...
The electric power supply cables must not show any damage. Have a qualified technician maintain the
device.
Clean the filters periodically.
Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
V. 03 – 08/02/2013
LX501
To
Description
255
output volume 0 ~ 100 %
255
fan speed 0 ~ 100 %
8
©Velleman nv