The 600 Ohm BAL OUT output is
transformer coupled from the sec-
ondary of the output transformer.
This output can be used simulta-
neously with any of the other out-
puts.
Do not terminate more than one
transformer-coupled loudspeaker
output simultaneously. All trans-
former-coupled loads are refer-
enced to COM.

Zone Outputs

Each of the four PZS
140RA outputs includes identical features and are
labeled as "zones." Both line-level and loudspeaker-level outputs are
provided. The power rating for the loudspeaker outputs is 35 Watts and
is transformer-coupled except for the 4 Ohm output.
XFMR - Each tap provides 35 Watts to constant voltage loads,
referenced to the COM connector. There are secondary transformer taps
for 70 Volt, 25 Volt and 8Ω loads (dom.) and 100 Volt, 70 Volt and 8Ω
loads (export).
DIRECT 4 OHM - This output is direct-coupled to the power amplifier
output and is referenced to ground.
600 OHM BAL OUT - Balanced 600 Ohm output for driving high
impedance sources. This signal is derived from the transformer
secondary and a passive line/impedance matching circuit. This output is
considered to be transformer-balanced and can be used simultaneously
with the loudspeaker-level output circuits.