ETQ
EASTERN TOOLS & EQUIPMENT INC
TROUBLESHOOTING
PROBLEM
1.Engine switch set to "OFF".
2.Fuel valve is in the "OFF" position.
3.Dirty air cleaner.
4.Out of gasoline.
5.Bad gasoline.
6.Loose or disconnected spark plug
Engine will not
wire.
start or runs
7.Bad spark plug.
rough when
8.Water in gasoline.
started
9.Overchoking.
10.Low oil level.
11.Excessive rich fuel mixture.
12.Intake valve stuck open or closed.
13.No compression.
1.Circuit breaker open.
Engine running
2.Defective cord or poor connection.
but no AC
3.Connected device is faulty.
output
4.Fault in generator.
Tel: (888)908-6200
CAUSE
17
Web Site: easterntools.com
SOLUTION
See How to Spray Wand paragraph
in the Operation Section.
Clean filter.
Ensure end of chemical hose is fully
submerged into chemical. Dilute
chemical.
Chemical should be the same
consistency as water.
Lengthen water supply hose instead
of high pressure hose.
Have parts cleaned or replaced by
AWSC.
1.Reset circuit breaker.
2.Check and repair.
3.Connect a good condition device.
4.Contact your local service dealer.