Culina IND60KC Manuel D'installation Et D'opération page 19

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ATTENTION: Under any circumstances, make sure the hob is well ventilated and
the air inlet and outlet are not blocked. Ensure the hob is in good work state. As
shown below
Note: The safety distance between the
hotplate and the cupboard above the hot-
plate should be at least 760mm.
A(mm)
760
B(mm)
50 minimum
C(mm)
20 minimum
D
Air intake
E
Air exit 5mm
X(mm)
50 minimum
Y(mm)
50 minimum
Before you install the hob, make sure that
• the work surface is square and level, and no structural members interfere with
space requirements
• the work surface is made of a heat-resistant material
• if the hob is installed above an oven, the oven has a built-in cooling fan
• the installation will comply with all clearance requirements and applicable stand-
ards and regulations
• a suitable isolating switch providing full disconnection from the mains power
supply is incorporated in the permanent wiring, mounted and positioned to com-
ply with the local wiring rules and regulations.
The isolating switch must be of an approved type and provide a 3 mm air gap
contact separation in all poles (or in all active [phase] conductors if the local
wiring rules allow for this variation of the requirements)
L(mm)
W(mm)
590
520
H(mm)
D(mm)
55
51
19
A(mm)
B(mm)
560
490
X(mm)
50 mini

Publicité