1. Vent hole. It is necessary that all submersible sump, effluent, and sewage
pumps capable of handling various sizes of solid waste be of the bottom
intake design to reduce clogging and seal failures. Vent hole should be
checked periodically for clogging. Water stream will be visible from this hole
during pump run periods.
2. Pump should be checked frequently for debris and/or build up which may
interfere with the float "on" or "off" position. Repair and service should be
performed by Zoeller Pump Company Authorized Service Station only.
3. Dewatering and effluent sump pumps are not designed for use in pits handling
raw sewage.
4. Maximum operating temperature must not exceed 104 ºF (40 ºC).
5. Do not operate a pump in an application where the Total Dynamic Head is
less than the minimum Total Dynamic Head listed on the Pump Performance
Curves.
6. For indoor use only.
7. DC emergency pumps are designed for handling clear water. Do not use in
septic tanks to pump effluent or sewage pits to pump sewage.
8. Repair and service of your DC backup system should be performed by an
authorized service station.
Manufacturer warrants, to the purchaser and subsequent owner during
the warranty period, every new product to be free from defects in material
and workmanship under normal use and service, when properly used and
maintained, for a period of one year from date of purchase by the end user. Parts
that fail within the warranty period, that inspections determine to be defective
in material or workmanship, will be repaired, replaced or remanufactured
at Manufacturer's option, provided however, that by so doing we will not be
obligated to replace an entire assembly, the entire mechanism or the complete
unit. No allowance will be made for shipping charges, damages, labor or
other charges that may occur due to product failure, repair or replacement.
This warranty does not apply to and there shall be no warranty for any material
or product that has been disassembled without prior approval of Manufacturer,
subjected to misuse, misapplication, neglect, alteration, accident or act of
God; that has not been installed, operated or maintained in accordance with
Manufacturer's installation instructions; that has been exposed to outside
substances including but not limited to the following: sand, gravel, cement,
mud, tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents,
etc.), or other abrasive or corrosive substances, wash towels or feminine
sanitary products, etc. in all pumping applications. The warranty set out in
the paragraph above is in lieu of all other warranties expressed or implied;
In those instances where damages are incurred as a result of an alleged pump failure,
the Homeowner must retain possession of the pump for investigation purposes.
There are millions of batteries manufactured each year, so it is impossible to guarantee consistent quality. A defective battery will never become fully
charged and may damage the charging circuits of the Control. It is for this reason that Zoeller offers its own line of batteries. We offer both a Water/Acid
Deep-Cycle Battery and maintenance-free AGM battery which can run the pump continuously for over 7½ hours. These times are based on continuous
pumping at 8' (2.4 mm) of static head. Actual times will vary depending on static head, volume of water entering the pit, and the condition of the battery.
Follow these recommendations:
• Use a B.C.I. size 27 deep-cycle battery, 175 minute reserve capacity, or larger
• Do NOT use a "maintenance-free" battery unless it is an AGM battery
• Replace your battery every 3 years
• Do not let corrosion build up on the battery terminals
• To check specific gravity, follow the instructions on a hydrometer (wet cell batteries only)
• Use of included plastic battery box is recommended to keep battery safe and clean
PROTECT YOUR WARRANTY:
• Water level in batteries must be checked once a month (wet cell batteries only)
CAUTION
SEE BELOW FOR LIST OF CAUTIONS
9. The installation of DC automatic backup pumps requires the use of a vari-
10. The tank is to be vented in accordance with local plumbing code. Pumps
11. According to the state of California (Prop 65), this product contains chemicals
NOTE: Pumps with the "UL" mark and pumps with the "US" mark are tested
to UL Standard UL778. CSA Certified pumps are certified to CSA Standard
C22.2 No. 108.
LIMITED WARRANTY
and we do not authorize any representative or other person to assume for us
any other liability in connection with our products.
Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky 40211,
Attention: Product Support Department to obtain any needed repair or
replacement of part(s) or additional information pertaining to our warranty.
MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL,
CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF
EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY
OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY
SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY.
Some states do not allow limitations on the duration of an implied warranty,
so the above limitation may not apply to you. Some states do not allow the
exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have other rights
which vary from state to state.
THE AQUANOT
®
© Copyright 2016 Zoeller
Co. All rights reserved.
®
2
able level float switch for operation. It is the responsibility of the installing
party, to ensure that the float switch will not hang up on the pump apparatus
or pit peculiarities and is secured so the pump will turn "on" and "off". It
is recommended that the pit be 18" in diameter or larger to accommodate
both a primary and a DC backup pump.
must be installed in accordance with the National Electrical Code and all
applicable local codes and ordinances. Pumps are not to be installed in
locations classified as hazardous in accordance with National Electrical
Code, ANSI/NFPA 70.