Wiring remarks
1. Third party equipment such as frequency inverters and electric motors
can generate excessive noise on the 230VAC / 400VAC power line.
This noise might be injected into the adjacent 12VAC power line and
disturb the power line communication towards the DURAVISION lights.
Keep 230VAC / 400VAC power line cables at least 50cm separated over their full
!
length from the 12VAC power line towards any RGB lights
Do not mix 12VAC and 230VAC / 400VAC power line cables into the same cable
!
trays
2. Floating cores in a multi-core cable are not allowed because it disturbs
PLC communication.
We recommend using 2 CORE cables for all Adagio Pro lights to avoid PLC
!
communication issues
Pool
house
(**)
230VAC
(**) Do not mix 12VAC and 230VAC / 400VAC power line cables into the
same cable trays
19
12VAC to lamps
Min. 50cm
Pool
230VAC / 400VAC to third party equipment