Troubleshooting
PROBLEM
The PLP-REM-350 doesn't react
to transmitter commands
The pool lights don't work
or don't change colors
correclty
Handheld transmitter does not
function anymore after firmware
update of the PLP-REM-350 for
LinkTouch compatibility
SOLUTION
•
Perform a RESET procedure
•
Check the battery of the handheld
transmitter (see p.16)
•
The transmitter is not paired-
correctly
with
Repeat the pairing process
•
Reduce the distance between hand-
held transmitter and PLP-REM-350
and/or remove obstacles
•
Check the General status light on
the logic board. If it's red, then
the secondary voltage is too high
(>14VAC) or there is a short circuit
•
Check the LED on the small DURA-
LINK circuit board (top right cor-
ner). This LED needs to blink each
time a transmitter button is pressed.
If the LED works, there might be a
problem with the logic board
•
Perform a RESET procedure
•
Check if all connections are made
according to the electrical scheme.
•
Switch the PLP-REM-350 to ON/
OFF mode (DIP switch nr 1) and
check if the lamps work
•
Buy a new TX868 transmitter that
has updated firmware
the
PLP-REM.
17