MALFUNCTION / CAUSES / SOLUTIONS
SYMPTOMS
There is no water at the lance outlet and / or no
water at the accessory outlet
Pump is noisy: Hose vibration.
The device does not switch off automatically
when I release the trigger of the gun.
Detergent is not released.
Water leak under the appliance: At the cylinder
head.
The device stops unexpectedly or after
INTENSIVE use
The motor "groans" but does not start
English
PROBABLE CAUSES
Problem with water supply
Pump inlet filter or faucet clogged
MULTIJET lance on LOW PRESSURE
Leak on an accessory
Valves blocked
Internal water seals worn
Pump inlet filter clogged
Leak on an accessory
Automatic stop microswitch damaged or not
working properly.
Switch on "0"
Detergent filter / injector / pipes clogged
Tank EMPTY
Worn or damaged seals
Cylinder head bent out of shape due to freezing
Use of a NON COMPLIANT extension
Motor overheating: Thermal cut out tripped
Problems with the electric supply
Problem with network voltage
Problem with motor ROTOR/STATOR
32
POSSIBLE SOLUTIONS
Check water supply
Clean the filter(s)
Pull the head towards you: HP position.
Check all connections
Contact VIRAX after sales service
Clean the filter(s)
Check all connections
Contact VIRAX after sales service
Change switch position: detergent selection.
Check & rinse the system with water.
Check level of the tank(s).
Contact VIRAX after sales service
Plug directly into the power outlet.
Allow the device to cool for 5 minutes and restart.
Check the power outlet and / or the circuit breaker.
Check if it is > to 215 V.